61 / GB
WARNING:
Make ground connection prior to any other electrical connections.
The internal and external units must be powered separately.
To prevent any risk, the power supply cable of the outdoor and indoor unit must only be replaced by the technicians of the
after-sales service.
External Unit electrical connection
• When removing the front panel, the electric parts appear at the front side.
• The power supply cables can be inserted into the precut holes (A) (Take off the knockout part)
• Be sure to fi x the power cable (B) and indoor/outdoor communication cable (C) with all the clips provided into the units and if necessary
add bundling bands sold on the market in order to be sure that they will not be in contact with the compressor and the hot pipes.
• To ensure good tensile strength, the electric cables must be fastened using the cable-holder on the plate (D).
• Connect the communication cable to the terminals as identifi ed by their respective numbers on the terminal block of indoor and
outdoor unit.
According to the installation instructions, all devices for disconnection from the power supply mains must have a contact opening (4 mm)
to allow total disconnection according to the conditions provided for the overvoltage class III.
Warning: Before obtaining access to terminals, all supply circuits must be disconnected.
L
N
N
L
MODBUS
MODBUS
GND A B
L N
GND A B
L1 L2 L3 N
Low voltage
Low voltage
External unit terminal block 1Ph
External unit terminal block 3Ph
High voltage
High voltage
A
B
C
D
Summary of Contents for 3300919
Page 8: ...8 IT 1106 383 1016 670 ø 10 374 1506 383 1016 670 ø 10 374 70 S 70 S T EXT 9 0 110 S T EXT ...
Page 22: ...22 IT SCHEMA ELETTRICO QUADRO UNITÀ ESTERNA 3 ph 1 ph ...
Page 50: ...50 GB 1106 383 1016 670 ø 10 374 1506 383 1016 670 ø 10 374 70 S 70 S T EXT 90 110 S T EXT ...
Page 64: ...64 GB 3 ph 1 ph ELECTRICAL SCHEME BOX OF EXTERNAL UNIT ...
Page 86: ...86 IT ...
Page 87: ...87 IT ...