77 / GB
MENU
SUB
-MENU
PA
R
AMETER
DESCRIPTION
RANGE
DEFAULT
5
5
8
Target deltaT for pump modulation cooling
[-5; -20°C]
-5°C
7
ZONE MODULE (if present)
7
1
Manual Mode
7
1
0
ZM Manual mode activation
OFF - ON
OFF
7
1
1
Z1 Pump control
OFF - ON
OFF
7
1
2
Z2 Pump control
OFF - ON
OFF
7
1
4
Z2 Mix Valve Control
OFF
Open
Close
OFF
7
2
General Zone Module
7
2
0
Hydraulic scheme defi nition
Not defi ned
MCD
MGM II
MGM III
MGZ I
MGZ II
MGZ III
MGM II
7
2
1
FlowT Off set
0
7
2
2
Auxiliary output setting
Heat request
External pump
Alarm
Heat request
7
2
3
External temperature correction
- 3 ÷ +3°C
0°C
7
3
Cooling
7
3
0
Flow_T_off set_Cool
[ 0÷ 6°C]
0°C
7
8
Error History
7
8
0
Last 10 Errors
7
8
1
Reset Error List
Reset? OK=Yes,esc=No
7
8
2
Last 10 Errors 2
7
8
3
Reset Error List 2
Reset? OK=Yes,esc=No
7
9
Reset Menu
7
9
0
Reset Factory Settings
Reset? OK=Yes,esc=No
17
HP System Parameters
17
0
User Parameters
17
0
0
CH mode
Mode Green
Mode Standard
Mode Green
17
0
1
Quiet Mode Activation
OFF - ON
OFF
17
0
2
Quiet Mode start time [hh:mm]
[00:00-24:00]
22:00
17
0
3
Quiet Mode end time [hh:mm]
[00:00-24:00]
06:00
17
0
4
Domestic Hot Water BOOST
OFF - ON
OFF
17
0
5
PV Delta T DHW setpoint temp.
0 ÷ 20°C
0°C
17
1
EM Input Output Confi guration
17
1
0
HV Input 1
Not Defi ned
Absent
EDF
SG1
Absent
17
1
1
HV Input 2
Not Defi ned
Absent
DLSG
SG2
Absent
17
1
2
HV Input 3
Not active
PV Integration Active
Not active
Summary of Contents for 3300919
Page 8: ...8 IT 1106 383 1016 670 ø 10 374 1506 383 1016 670 ø 10 374 70 S 70 S T EXT 9 0 110 S T EXT ...
Page 22: ...22 IT SCHEMA ELETTRICO QUADRO UNITÀ ESTERNA 3 ph 1 ph ...
Page 50: ...50 GB 1106 383 1016 670 ø 10 374 1506 383 1016 670 ø 10 374 70 S 70 S T EXT 90 110 S T EXT ...
Page 64: ...64 GB 3 ph 1 ph ELECTRICAL SCHEME BOX OF EXTERNAL UNIT ...
Page 86: ...86 IT ...
Page 87: ...87 IT ...