78 / GB
MENU
SUB
-MENU
PA
R
AMETER
DESCRIPTION
RANGE
DEFAULT
17
1
3
AUX Input 1
None
Humidistat sensor
None
17
1
4
AUX Output 1 (AFR)
None
Fault alarm
Humidistat alarm
External heat request.
None
17
1
5
AUX Output 2
None
Fault alarm
Humidistat alarm
External heat request
None
17
2
Energy manager parameter 1
17
2
0
Hydraulic scheme
None
Plus
Compact
Flex
Hp Water Heater
None
17
2
1
Thermoregulation
Absent
Present
Present
17
2
2
ECO / COMFORT
Eco Plus
Eco
Average
Comfort
Comfort Plus
Average
17
2
3
FlowT HP Off set
0 ÷10°C
2°C
17
2
4
Boost Time
0 ÷ 60 min
16 min.
17
2
5
External temperature correction
- 3; + 3°C
0°C
17
2
6
Active Resistance Stages
1 Stage
2 Stages
3 Stages
2 Stages
17
2
7
Pro-Tech anode active
OFF - ON
OFF
17
2
9
Antiblocking pump enable
OFF - ON
17
3
Central Heating
17
3
0
CH pump prerun time
30 ÷ 255 sec.
30 sec.
17
3
1
Time for prerun new attempt
0 ÷ 100 sec.
90 sec.
17
3
2
CH Pump Overrun
0 ÷ 16 min.
3 min.
17
3
3
Pump Speed Control
Low speed
High speed
Modulating
Modulating
17
3
4
Delta T Pump Setpoint
5 ÷ 20°C
5°C
17
3
5
Min Pressure
0,3 ÷ 0,4 bar
0,4 bar
17
3
6
Warning Pressure
0,4 ÷ 0,8 bar
0,6 bar
17
3
7
Max PWM Pump
min PWM ÷ 100%
100%
17
3
8
Min PWM Pump
80% ÷ max PWM
100%
17
3
9
Floor drying Flow Set Point T
25 ÷ 60°C
55°C
17
4
Cooling
17
4
0
Cooling mode activation
Cooling not active
Cooling active
Cooling not active
17
4
1
Cooling anticycling time
0 -10 min.
0 min.
17
4
2
DeltaT_HP_Flow_Comp
-10 ÷ 0°C
-2°C
17
5
Domestic Hot Water
17
5
0
DHW Comfort Setpoint T
35 ÷ 65°C
55°C
17
5
1
DHW Reduced Set Point T
35°C - Par. 15.5.0
35°C
Summary of Contents for 3300919
Page 8: ...8 IT 1106 383 1016 670 ø 10 374 1506 383 1016 670 ø 10 374 70 S 70 S T EXT 9 0 110 S T EXT ...
Page 22: ...22 IT SCHEMA ELETTRICO QUADRO UNITÀ ESTERNA 3 ph 1 ph ...
Page 50: ...50 GB 1106 383 1016 670 ø 10 374 1506 383 1016 670 ø 10 374 70 S 70 S T EXT 90 110 S T EXT ...
Page 64: ...64 GB 3 ph 1 ph ELECTRICAL SCHEME BOX OF EXTERNAL UNIT ...
Page 86: ...86 IT ...
Page 87: ...87 IT ...