Malfunctions:
The green POWER indicator light does
not illuminate.
The motor does not start.
The indicator lights are on but the light is
dim.
a) The alarm sounds.
b) The alarm sounds and the two yellow
indicator lights flash.
c) The alarm sounds and the two yellow
indicator lights as well as the green one
flash.
The green POWER indicator light flashes.
The refrigerator and the freezer do not
cool well.
The food inside the refrigerator is
beginning to freeze.
The motor runs continuously.
The Aircooler fan does not rotate
The appliance makes a lot of noise.
The back wall of the refrigerator unit is
covered in frost or droplets of water
There is water at the bottom of the
refrigerator.
Possible causes / Solutions:
The plug has not been inserted into the electrical socket, or not far enough to
make contact, or there is no power in the house.
The appliance comes with a motor protection control (
see Start-up and use
).
Pull out and reverse the plug before putting it back in the socket.
a)
The refrigerator door has remained open for more than two minutes (the
buzzer will stop sounding when you shut the door) or the correct switching-off
procedure was not followed (
see Maintenance
).
b)
The temperature in the freezer is too high. Check the quality of the food
products and dispose if necessary.
c)
The temperature in the freezer has reached a dangerous level. The food must
be disposed immediately.
b/c)
In both these cases the freezer will maintain a temperature of about 0°C so
that the food does not re-freeze.
To turn off the acoustic signal open and close the refrigerator door. To
restore normal operation bring the FREEZER OPERATION knob setting to
(off) and turn the appliance on again.
The appliance is not operating correctly. Contact the Technical Assistance
Centre.
The doors do not close properly or the seals are damaged.
The doors are opened too frequently.
The OPERATION knobs are not on the correct setting (
see Description
).
The refrigerator or the freezer have been over-filled.
The REFRIGERATOR OPERATION knob is not on the correct setting (
see
Description
).
The food is in contact with the back inside wall of the refrigerator.
The SUPER FREEZE button has been pressed (rapid freezing): the yellow
SUPER FREEZE light is on or flashing (
see Description
).
The door is not closed properly or is continuously opened.
The outside ambient temperature is very high.
The thickness of the frost exceeds 2-3 mm (
see Maintenance
).
The refrigerator door is open.
The Aircooler system is only activated automatically when it becomes
necessary to restore perfect operational conditions inside the refrigerator
compartment.
The appliance has not been installed on a level surface (
see Installation
)
.
The appliance has been installed between cabinets that vibrate and make
noise.
The internal refrigerant makes a slight noise even when the compressor is off.
This is not a defect, it is normal.
This shows the appliance is operating normally.
The water discharge hole is blocked (
see Maintenance
).
+ buzzer
Heating
danger
+ buzzer
Heating
is excessive
Summary of Contents for BMBL 2021 C
Page 12: ...12 I 195062791 03 02 2007 Xerox Business Services ...
Page 24: ...24 GB 195062791 00 07 2007 Xerox Business Services ...
Page 36: ...36 F 195062791 00 02 20075 Xerox Business Services ...
Page 48: ...48 E 195062791 00 02 2007 Xerox Business Services ...
Page 60: ...60 PT 195062791 00 02 2007 Xerox Business Services ...