background image

Installation

!

 Before operating your new appliance please read this 

instruction booklet carefully. It contains important information 

for safe use, installation and care of the appliance.

!

 Please keep these operating instructions for future 

reference. Pass them on to possible new owners of the 

appliance.

Compliance with standards

This cooktop must be installed by an authorised person in 

accordance with the requirements of local gas and electrical 

authorities, as well as the latest published versions of the 

following standards:

•  AS/NZS 5601 Gas installation and pipe sizing

•  SAA Wiring Rules.

Positioning

!

 Keep packaging material out of the reach of children. It can 

become a choking or suffocation hazard (

see Precautions 

and tips

).

!

 The appliance must be installed by a qualified and 

authorised professional according to the instructions 

provided. Incorrect installation may cause harm to people 

and animals or may damage property.

Kitchen Ventilation

Where the total input of all appliances exceeds 3 MJ/h for 

each cubic metre of the room or enclosure volume, the 

space shall be ventilated by one of the methods detailed 

below. For the purpose of assessing the adequacy of 

ventilation, the space that cannot be isolated by doors is 

the ‘volume of a room’.

Natural ventilation direct from outside

Two permanent openings shall be provided directly to 

outside. The openings shall be located to ensure the 

distance between the top of the upper opening and the 

ceiling of the room or enclosure, and the distance between 

the bottom of the lower opening and the floor of the room 

or enclosure does not exceed 5% of the height of the room 

or enclosure. The minimum free ventilation area provided 

by each opening shall be calculated using the following 

formula:

  A = 3 × T

where

  A = the minimum free ventilation area (cm

2

)

  T = the total gas consumption of all appliances (MJ/h)

The minimum vertical dimension of any free ventilation 

opening shall be 6 mm.

NOTE 1 

When used in this Clause, the term ‘directly to 

outside’ means any one of the following options, provided 

that the ventilation path is unobstructed by building material 

or insulation:

  (a) Directly through an outside wall (preferred option).

  (b) Through to an outside wall but offset.

  (c) Into a cavity ventilated to outside.

  (d) Into an under floor space ventilated to outside.

  (e) Into a roof space ventilated to outside.

NOTE 2 

The two openings may be combined provided that 

the top and bottom of the opening reach the limits set by 

this Clause.

Natural ventilation via adjacent room

Two permanent openings shall be provided in the room 

or enclosure. The openings shall be located to ensure the 

distance between the top of the upper opening and the 

ceiling of the room or enclosure, and the distance between 

the bottom of the lower opening and the floor of the room 

or enclosure does not exceed 5% of the height of the room 

or enclosure.

The minimum free ventilation area provided by each opening 

shall be calculated using the following formula: 

  A = 6 × T

where

  A = the minimum free ventilation area (cm

2

)

  T = the total gas consumption of all appliances (MJ/h)

These requirements shall apply to all subsequent rooms 

until a room is ventilated to outside, in accordance with the 

previous section, or the total input of the appliances does 

not exceed 3 MJ/h for each cubic metre of the total volume 

of the enclosure and rooms.

The minimum vertical dimension of any free ventilation 

opening shall be 6 mm.

NOTE: 

The two openings may be combined provided that 

the top and bottom of the opening reach the limits set by 

this Clause.

•  Liquid petroleum gas sinks to the floor as it is heavier 

than air. Therefore, rooms containing LPG cylinders must 

also be equipped with vents to allow gas to escape in 

the event of a leak. As a result LPG cylinders, whether 

partially or completely full, must not be installed or stored 

in rooms or storage areas that are below ground level 

(cellars, etc.). It is advisable to keep only the cylinder 

being used in the room, positioned so that it is not subject 

to heat produced by external sources (ovens, fireplaces, 

stoves, etc. ) which could raise the temperature of the 

cylinder above 50°C.

Adjacent cabinetry

The location of connection points is given in the table on 

page 5 . For trouble-free operation of appliances installed in 

housing units, the minimum distances shown in fig.4 should 

be observed.  It is recommended that the adjacent kitchen 

surfaces should be capable of withstanding temperatures 

of 65°C. Also, the following must be observed:

•  The appliance should be installed next to cabinetry which 

is no taller than the top of the cooker hob. 

•  The  wall  in  direct  contact  with  the  back  panel  of  the 

cooker must be made of non-flammable material.  

During operation of the cooker, the back panel of the 

cooker could reach a temperature of 50°C above room 

temperature.

•  Kitchen  cabinets  installed  next  to  the  cooker  that  are 

higher than the top of the hob, must be at least 600 mm 

from the edge of the hob itself.

•  If the hood is installed below a wall cabinet, the latter 

must be at least 700 mm (millimetres) above the surface 

of the hob.

AUS

7

Summary of Contents for PC 640 NTX AUS

Page 1: ...ns and tips 13 Maintenance and care 13 Troubleshooting 14 Sommaire Mode d emploi 1 Avertissements 2 Assistance 4 Description de l appareil 5 Installation 15 Mise en marche et utilisation 21 Précautions et conseils 22 Nettoyage et entretien 23 Anomalies et remèdes 23 Sumario Manual de instrucciones 1 Advertencias 3 Asistencia 4 Descripción del aparato 6 Instalación 24 Puesta en funcionamiento y uso...

Page 2: ... hob guards can cause accidents Avertissements ATTENTION Cet appareil ainsi que ses partiesaccessiblesdeviennenttrèschauds pendant leur fonctionnement Il faut faire attention à ne pas toucher les éléments chauffants Ne pas faire approcher les enfants de moins de 8 ans à moins qu ils ne soient sous surveillance constante Le présent appareil peut être utilisé par des enfants de plus de 8 ans et par ...

Page 3: ...de modo seguro y comprenden los peligros relacionados con el mismo Los niños no deben jugar con el aparato Las operaciones de limpieza y de mantenimiento no deben ser realizadas por niños sin vigilancia ATENCIÓN Dejar un quemador con grasas o aceites sin vigilancia puede ser peligroso y provocar un incendio NUNCA intente apagar una llama incendio con agua se debe apagar el aparato y cubrir la llam...

Page 4: ...maremos sobre el fantástico plan de ampliación de garantía hasta 5 años Consiga una cobertura total adicional de Piezas y componentes Mano de obra de los técnicos Desplazamiento a su domicilio de los técnicos Y NO PAGUE AVERIAS NUNCA MAS Servicio de asistencia técnica SAT Llame al 902 133 133 y nuestros técnicos intervendrán con rapidez y eficacia devolviendo el electrodoméstico a sus condiciones ...

Page 5: ...extinguished Only available on certain models Description de l appareil Vue d ensemble 1 Grilles support de CASSEROLES 2 BRÛLEURS À GAZ 3 Manettes de commande des BRÛLEURS GAZ 4 Bougie d allumage des BRÛLEURS GAZ 5 DISPOSITIF DE SÉCURITÉ BRÛLEURS GAZ ils ont plusieurs dimensions et puissances Choisissez celui qui correspond le mieux au diamètre de votre casserole Manettes de commande des BRÛLEURS ...

Page 6: ...MADORES A GAS son de distintas dimensiones y potencias Elija siempre el más adecuado para el diámetro del recipiente que va a utilizar Mandos de los QUEMADORESAGAS para la regulación de la llama Bujía de encendido de los QUEMADORES A GAS permite el encendido automático del quemador DISPOSITIVO DE SEGURIDAD si se apaga accidentalmente la llama interrumpe la salida de gas Presente sólo en algunos mo...

Page 7: ...ach the limits set by this Clause Natural ventilation via adjacent room Two permanent openings shall be provided in the room or enclosure The openings shall be located to ensure the distance between the top of the upper opening and the ceiling of the room or enclosure and the distance between the bottom of the lower opening and the floor of the room or enclosure does not exceed 5 of the height of ...

Page 8: ...tallation cavity should have the dimensions indicated in the figure Fastening hooks are provided allowing you to fasten the hob to tops that are between 20 and 40 mm thick To ensure the hob is securely fastened to the top we recommend you use all the hooks provided 555 mm 55 m m 4 7 5 m m 600mm min 420mm min 650mm min Hook fastening diagram 20 30 Hooking position Hooking position for top H 20mm fo...

Page 9: ...of the appliance to the right fig 8 or an approved flexible hose of class B or D Should it be necessary to turn the fitting the gasket supplied with the appliance must be replaced If a flexible hose is used it should be as short as possible with a maximum length of 1 2 metres The flexible connection must be approved to class B or D of AS NZS1869 as a minimum it should not be bent kinked or compres...

Page 10: ... be different or vary slightly from the recommended pressure a suitable pressure regulator must be fitted to the inlet pipe in order to comply with current national regulations Post Installation Checks Perform post installation checks and ensure proper and safe operation before leaving Test all burners individually and in combination Leak Check Ensure all gas control knobs are in the Off position ...

Page 11: ...80 0 50 0 70 0 70 3 3 5 5 9 0 16 5 34 3 PK 640 R GH AUS R DC S A Burner and nozzle specifications Gas Connection Natural Gas 1 0 kPa ULPG 2 75 kPa Auxiliary Burner Semi Rapid Burner Wok Burner Dual Control Wok Burner Total Ø Injector mm GC MJ hr Ø Injector mm GC MJ hr Gas Inlet fitting 1 2 BSP male thread Location of gas inlet 40 mm from rear edge 40 mm from right hand edge 0 85 1 10 1 19 x2 0 80 ...

Page 12: ...The double flame burner This gas burner consists of two concentric flame rings that can operate jointly or independently in case of dual control only As the burner is fitted with a safety device the knob should be pressed down for approximately 2 3 seconds until the device keeping the flame automatically alight heats up Dual control Each ring comprising the burner has its own control knob The knob...

Page 13: ...t be operated by people including children with reduced physical sensory or mental capacities by inexperienced individuals or by anyone who is not familiar with the product These individuals should at the very least be supervised by someone who assumes responsibility for their safety or receive preliminary instructions relating to the operation of the appliance Do not let children play with the ap...

Page 14: ...here are no interruptions in the gas and electrical supplies and in particular that the gas valves for the mains are open The burner does not light or the flame is not even around the burner Check whether The gas holes on the burner are clogged All the movable parts that make up the burner are mounted correctly There are draughts near the appliance The flame dies in models with a safety device Che...

Page 15: ... un espace situé sous le sol et ventilé vers l extérieur e Dans un espace en toiture ventilé vers l extérieur NOTE 2 Les deux ouvertures peuvent être combinées à condition que le haut et le bas de l ouverture atteignent les limites fixées dans cette notice Ventilation naturelle par le biais d une pièce adjacente Deux ouvertures permanentes doivent être ménagées dans la pièce ou l enceinte Les ouve...

Page 16: ...tilation forcée pour assurer son refroidissement il faut créer des ouvertures d aération afin de permettre une ventilation adéquate à l intérieur du meuble au moins 200 cm en bas pour l arrivée d air et au moins 120 cm en haut pour la sortie Il faut en outre installer une planche de bois sous la plaque de cuisson en guise d isolation à une distance minimale de 15 mm du meuble Avant de procéder à l...

Page 17: ...ne cette cuisinière est configurée pour fonctionner au gaz naturel Pour utiliser la cuisinière avec du gaz liquéfié ou au gaz naturel après l avoir utilisée précédemment au gaz liquéfié veuillez suivre les indications reportées plus loin dans cette section Installez le régulateur fourni pour le gaz naturel le cas échéant à l arrière de l appareil et le plus près possible de l appareil Il est recom...

Page 18: ...x parties distinctes voir figures 2 Dévissez les injecteurs à l aide d une clé à douille de 7 mm Remplacez les injecteurs par des modèles d injecteurs adaptés pour le nouveau type de gaz voir Tableau 1 Les deux injecteurs ont le même diamètre d orifice 3 Remettez tous les composants en place en répétant les opérations ci dessus dans le sens inverse Réglage de l air primaire des brûleurs Ne nécessi...

Page 19: ... S il y a beaucoup de jaune si la flamme s éteint ou bien si la combustion est excessivement bruyante vérifiez la pression et ajustez la au niveau du régulateur si cela s avère nécessaire Si vous ne parvenez pas à un fonctionnement satisfaisant contactez votre lieu d achat ou leur technicien d entretien agréé Fonctionnement de l allumeur Vérifiez que l allumeur de chaque brûleur parvient à enflamm...

Page 20: ... mm du bord arrière 40 mm du bord latéral PK 640 R GH AUS R DC S A Caractéristiques des brûleurs et des injecteurs Raccordement gaz Gaz naturel 1 0 kPa Gaz liquéfié 2 75 kPa 0 85 1 10 1 19 x2 0 80 1 19 1 19 3 6 6 0 13 5 17 0 40 1 0 50 0 64 0 70 x2 0 50 0 70 0 70 3 3 5 5 13 0 16 5 38 3 Diamètre des injecteurs mm Diamètre des injecteurs mm Consommation de gaz MJ hr Consommation de gaz MJ hr Brûleur ...

Page 21: ...issance max 1 puissance min Ce système assure un réglage parfait de la flamme et permet de toujours obtenir le même résultat de cuisson car il est plus facile de régler le niveau de puissance désiré Le brûleur à deux flammes Ce brûleur à gaz est formé de deux anneaux de flamme concentriques pouvant fonctionner ensemble ou séparément uniquement dans le cas de double commande Le brûleur étant équipé...

Page 22: ...ouchés Contrôlez toujours que les manettes sont bien dans la position quand l appareil n est pas utilisé Ne tirez surtout pas sur le câble pour débrancher la fiche de la prise de courant N effectuez aucune opération de nettoyage ou d entretien sans avoir auparavant débranché la fiche de la prise de courant En cas de panne n essayez en aucun cas d accéder aux mécanismes internes pour tenter de répa...

Page 23: ... couvercle en verre pour éviter que les caoutchoucs sur le verre s abîment Entretien robinets gaz Il peut arriver qu au bout d un certain temps un robinet se bloque ou tourne difficilement Il faut alors le remplacer Cette opération doit être effectuée par un technicien agréé par le fabricant Anomalies et remèdes Il peut arriver que l appareil ne fonctionne pas ou ne fonctionne pas très bien Avant ...

Page 24: ... e inferior de las aberturas respeten los límites establecidos por esta cláusula Ventilación natural a través de una habitación adyacente Debe haber dos aberturas permanentes en la habitación o recinto La distancia entre el borde superior de la abertura superior y el techo de la habitación o recinto y la distancia entre el borde inferior de la abertura inferior y el piso de la habitación o recinto...

Page 25: ...a instalación quite las rejillas y los quemadores de la encimera e inviértala teniendo cuidado de no dañar los termopares y las bujías Coloque las juntas suministradas con el aparato en los bordes externos de la encimera para impedir el paso de aire humedad y agua ver la figura Para que la aplicación sea correcta controle que las superficies que se deben sellar estén limpias secas y sin grasa o ac...

Page 26: ...ula aislante y una unión para facilitar la desconexión en caso de reparaciones Estos componentes deberían quedar en una posición accesible Comprobar que la presión del suministro de gas corresponda a los valores indicados en la Tabla 1 Especificaciones del hornillo y la boquilla Esto garantizará el uso seguro y la longevidad del aparato manteniendo eficiente el consumo de energía Conexión del tubo...

Page 27: ...e la varilla del grifo ver la figura Regulación DCDR interno Regulación DCDR total 3 Una vez ajustada la llama baja con el hornillo encendido cambiar rápidamente la posición del pomo varias veces del mínimo al máximo y viceversa asegurándose de que la llama no se apague 4 Algunos aparatos tienen incorporado un dispositivo de seguridad termopar Si el dispositivo no funciona cuando los hornillos est...

Page 28: ...esultado no es satisfactorio contactar con el vendedor y con el agente para pedir asistencia Ajuste de llama baja Controlar el ajuste de la llama baja de cada hornillo para asegurarse de que el fuego al mínimo no pueda ser apagado por corrientes de aire Encender el hornillo Girar el mando hasta la posición mínima Asegurarse de que la llama sea estable y no se apague por corrientes de aire Para aju...

Page 29: ... 0 80 0 50 0 70 0 70 3 3 5 5 9 0 16 5 34 3 PK 640 R GH AUS R DC S A Características de los quemadores e inyectores Conexión del gas Gas natural 1 0 kPa GLP 2 75 kPa Empalme de entrada del gas Rosca 1 2 BSP macho Ubicación de la entrada de gas 40 mm desde el borde posterior 40 mm desde el borde lateral Quemador auxiliar Quemador semirápido Quemador wok de triple llama Quemador Doble llama Total 0 8...

Page 30: ...correspondiente símbolos y en las encimeras que poseen pantalla a través del encendido de los LED 5 máx potencia 1 mín potencia El sistema garantiza una perfecta regulación de la llama y permite obtener el mismo resultado de cocción individualizando más fácilmente el nivel de potencia deseado El quemador de dos llamas Este quemador a gas está formado por dos fuegos concéntricos que pueden funciona...

Page 31: ...s calientes del horno No obstruya las aberturas de ventilación y de eliminación del calor Controle siempre que los mandos estén en la posición cuando no se utiliza el aparato No desconecte el aparato de la toma de corriente tirando del cable sino sujetando el enchufe No realice la limpieza o el mantenimiento sin haber desconectado primero el aparato de la red eléctrica En caso de avería no acceda ...

Page 32: ...os tapones de goma del vidrio Mantenimiento de las llaves de gas Con el tiempo puede suceder que una llave se bloquee o presente dificultad para girar en esos casos será necesario proceder a la sustitución de dicha llave Esta operación la debe efectuar un técnico autorizado por el fabricante Anomalías y soluciones Puede suceder que la encimera no funcione o no funcione bien Antes de llamar al serv...

Reviews: