Model ATS1155
➊
➌
English
Heavy Duty 4 LED RAS
M
OUNTING THE UNIT
The unit is supplied as a kit consisting of a keypad and separate electronics. It
can be mounted on the surface, or if required, installed in a custom enclosure.
Note:
Mount the unit at an acceptable height so that it is easy to
operate without needing to reach up, and the LED’s can be easily
seen.
C
ONNECTING CONTROL PANEL TO KEYPAD
(
FIGURE
➌
)
Refer to the ATS control panel installation guide for instructions.
RAS
DIP SWITCH SETTINGS
(
FIGURE
➊
)
①
SW1 "ADDRESS" dip switches 1 to 4 are used to identify this RAS number.
LED’
S
(
FIGURE
➊
)
➂
TX LED flashes to indicate the arming station (RAS) is replying to polling
from the ATS control panel.
LED I
NDICATIONS ON KEYPAD
(
FIGURE
➌
)
(L1) ACCESS (Disarmed) Illuminates when at least one of the areas
assigned to the arming station is disarmed,
and
when a PIN is
used to open a door, the LED flashes for the unlock time.
(L2) ALM
(Alarm) Illuminates when an alarm has occurred in one of the
areas assigned to the arming station.
(L3) RDY
•
When connected to the control panel, it illuminates when
the area is ready to be armed (system clear). ie. all inputs
normal,
or
•
When connected to an 4-door/4-lift DGP, it illuminates
when ready to accept a PIN code.
(L4) SECURE Illuminates when the area is armed.
When All LED’s are flashing, the arming station is not being polled.
C
ONNECTIONS
J2
TERMINALS
(
FIGURE
➊
)
Power supply. If the distance between the arming station and the
control panel does not exceed 100m, then the arming station can be
powered using the Comms + and – from the control panel. Otherwise
use AUX PWR from DGP’s or an auxiliary power supply.
D+
Data positive and data negative connection of the databus.
D -
Remote units can be up to 1.5 km from the ATS control panel.
IN
A request to exit button (normally open, momentary push-button switch)
can be connected across “IN” and “-“. When pressed, this button
controls the request to exit function.
OUT Open collector output, 50 mA maximum. It is the first output of the
output control group that is assigned to this arming station.
L
INKS
(
FIGURE
➊
)
④
GND
Must remain fitted.
⑤
TERM
Fitted if this device is the last device on the system databus.
For more details see the ATS control panel installation guide.
C
ONNECTION FROM ELECTRONICS TO KEYPAD
(
②
FIGURE
➊
)
Via a standard cable supplied with this product
.
+
-
⑤
③
④
J2
①
1 2 3 4
IN OUT D- D+ - +
②
ATS4000
Dipswitches
➋
J10
1
2
3
4
ON
RAS 1
1
2
3
4
ON
RAS 2
1
2
3
4
ON
RAS 3
1
2
3
4
ON
RAS 4
1
2
3
4
ON
RAS 5
1
2
3
4
ON
RAS 6
1
2
3
4
ON
RAS 7
1
2
3
4
ON
RAS 8
1
2
3
4
ON
RAS 9
1
2
3
4
ON
RAS 10
1
2
3
4
ON
RAS 11
1
2
3
4
ON
RAS 12
1
2
3
4
ON
RAS 13
1
2
3
4
ON
RAS 14
1
2
3
4
ON
RAS 15
1
2
3
4
ON
RAS 16
Access
RDY
ALM
Secure
1
105066