5. Cleaning the burner. Remove the fixing bolts
from the burner and loosen the hose and electric
connections. Pull out the burner.
7. Emptying the ash. Pull out the ash box. Empty
the ash into a decked fireproof container outdo
-
ors. Because of the fire risk, the container must
not include anything but ash.
9. Emptying the ash is even easier with an ash
cyclone, which works like a vacuum cleaner. It is
important not to vacuum hot ash because of the
fire risk.
11. Remaining ash which is collected in a fire
-
proof container…
12. … can be used as a fertilizer.
6. Remove the ash by brushing the walls of the
combustion chamber. Clean the burn pot and
the air cracks.
8. Ash compression lengthens the interval bet
-
ween emptying the ash. The ash tightens when
the adjuster is moved back and forth.
MAINTENANCE, CARE, SWEEPING