ARITERM SWEDEN AB
Installation, Operation & Maintenance -
2009.02.18- 3/32
DIMENSIONS / ITEMS INCLUDED IN THE DELIVERY / TECHNICAL DATA - B 20
TECHNICAL DATA
Performance
Output using pellets
Power of ignition resistor
Normal power consumption
8 - 20 kW
450 W
60 W
Dimensions
Dimensions (width x depth x height)
Weight
Water contents
Weight (burner)
604 x 925 x 1500 mm
245 kg
140 l
23 kg
Design values
Design pressure
Design temperature
Recommended draught
0,5 - 1,5 bar
max 120
o
C
5-20 Pa
Connections
Expansion
Drain
Flue pipe connection
Recommended chimney diameter and
length
DN 25 male
DN 15 female
Ø 102 mm
Ø 100 mm, length min 5 m
Electrical data
Power supply
Supply cable
Fuse size
Power in operation
400 V 50 Hz
MMJ 4x2,5s
3x16 A
9000 W
Part Number
B 20 (
•
part.no. 4010)
Standard delivery
Shunt valve ESBE TM 20
•
Sweeping gear
•
Combination flue for horizontal and vertical installation (
•
part no. 5206)
Accessories
Burner assembly kit
•
Shunt outlet
•
B 20
1. Drain DN 15, female
2. Flue pipe Ø 139 mm
3. Additional shunt (optional)
4. Expansion DN 25, male
5. Shunt outlet
a) Feed line Cu 22 / DN 20
b) Return line Cu 22 / DN 20
6. Cold water Cu 22
7. Hot water Cu 22
8. Cabel bushing
9. Sweeping hatch
10. Ash box
11. Return line DN 25 female
12. Air valve
13. Ash compression
Ø102
Ø102
604
590
1500
180
750
1460
1710
215
556
925
155
60
335
Ø114
9
2
3
4
5b
5a
6
7
8
1
13
12
10
11
500
65
A-dimensions including comb.flue pipe is app. 1710 mm
Comb.flue pipe
440
107
Ø114
Ø114
50
Summary of Contents for Biomatic plus 50
Page 10: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 10 32 WIRING DIAGRAM ...
Page 28: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 28 32 NOTES ...
Page 29: ...ARITERM SWEDEN AB Installation Operation Maintenance 2009 02 18 29 32 NOTES ...