PELLET STOVE KMP EKERUM / NEPTUNI
ARITERM SWEDEN AB
Installation Instructions -
2011.08.19
- 10
/24
Otherwise the electronics manage all processes as follows:
•
START
1.6.1 control process
Time
Events
Comments
0 secs
• Firing element on.
• The firing element symbol illuminates.
120 secs
• The motor symbol illuminates.
• The feeder starts.
220 - 330 secs
• The feeder stops (Starter dose)
.
• The combustion fans starts puls-
ing and stops twice.
• The motor symbol goes out.
The time depends on the set pellet
amount at ignition.
Pellet level should be approx. 5
mm above the firing element hole.
The flame symbol is displayed as
long as the flame sensor indicates
a flame.
Approx 6 min
• Hot air fan on.
• If the flame sensor indicates
flame, the firing element is shut
off, the flame symbol illuminates
and the firing element symbol
goes out.
Approx 8 min
• The feeder on at low output.
• Maximum time for firing element.
Runs from 1.8 - 6 seconds every
10th second.
Approx 10 min
• Operating phase.
The thermostat regulates the
output according to the set values.
•
HIGH OUTPUT
After "START".
•
”HiPower”
scrolls through the
display.
• The feeder runs according to
”FeedHi”.
• Combustion fan ”Fan HI”
The time depends on the set fuel
amount at high output.
Every 10 seconds.
• Set temperature and room
temperature are compared.
If the room temperature falls below
the set temperature by less than 1˚C
the program switches to low output.
• The flame sensor is checked
If no flame is detected, the exclama-
tion mark illuminates and the stove
goes into “Operational stoppage”
mode.
After "Start".
• ”LoPower”
scrolls through the
display.
• The feeder runs according to
”FeedLO”
• Combustion fan ”Fan LO”
The time depends on the set
pellet amount at low output.
Every 10 seconds.
• Set temperature and room
temperature are compared.
If the room temperature reaches
the set stop temperature, the pro-
gram switches to extinguishing and
then to ”Standby”.
• The flame sensor is checked
If no flame is detected, the exclama-
tion mark illuminates and the stove
goes into “Operational stoppage”
mode.
0 secs
6 min
• Combustion fan stops
• The hot air fan stops
•
EXTINGUISHING
Time
Events
Comments
•
LOW OUTPUT
• The feeder stops
• Combustion fan runs at max.
• The hot air fan runs
To blow ash out of the burner
crucible