3.4 Sweeping
The chimney must be swept twice a year.
Remove the cleaning hatch, under the top plate / stone
(4 x Allen screws).
The flue and its connection and the area underneath the
cleaning hatch must be cleaned at least once between the
chimney sweep’s visits. Sweeping of the stove is carried out
once a week during the firing season using the integrated
soot rakes.
They are located behind the front panel and must be
pulled backwards and forwards a couple of times each,
starting from above.
To prevent ash falling onto the floor, move the ash
box before sweeping, as follows.
Measurement hole
Remove the soot rakes as follows:
1. The silicon seal seals against the stove body.
2. Slacken off the nut a couple of turns.
3. Press the soot rake upwards or downwards.
4. Pull the soot rakes (in pairs) straight out.
5. The soot rakes are sealed in reverse order.
The chimney must be checked for blockages if
unused for a prolonged period.
1. Lift out the ash box and turn it
with the angled panel facing inward.
2. Place the angled panel between
the two curved panels (1 and 2) under
the convection tubes.
3. Lift the ash box up and...
4 ...slide it in as far as possible. You can
now pull the soot rakes and allow the
ash to drop down into the ash box.
Fig. 9