7
TEMPERATURE CONTROL VALVE
The Ariterm Vedo boiler must be installed in connection with a warm water accumulator. This
improves its functionality and extends its life span substantially.
By installing the boiler as presented here, it is possible to make the boiler temperature rise
quickly and to maintain a steady, high temperature when the boiler is being used. The fact that
water is layered in the accumulator ensures a quick supply of warm water soon after heating
starts. The heating circuit and household water circuit are connected to the accumulator.
Installing a temperature control valve to wood-fired boiler with a cooling spi-
ral
The Pressure Equipment Directive requires that manually-filled wood-fired boilers must be
equipped with a safety device, which prevents the boiler from overheating. We recommend the
SYR 3065 temperature control valve for this boiler. This does not, however, replace other safety
devices, such as a pressure relief valve.
Installation
The temperature control valve is connected to the cooling spiral so that, when the valve is activa-
ted, it sends hot water down the drain. The temperature sensor is installed on the sleeve on the
upper part of the boiler, using a DN 15 x 150 well.
TECHNICAL DATA
Max pressure of incoming water
10 bar
Opening temperature
97
° C
Temperature control valves are available from Ariterm
Product Number 5012921