background image

Ranger

®

 Blut-/Flüssigkeitswärmeeinheit

Betriebshandbuch

Réchauffement de sang/soluté Ranger

Manuel de l’utilisateur

Sistema per il riscaldamento di sangue e 

di fluidi Ranger

Manuale d’uso

Calentamiento de fluidos /plasma

Manual del usuario

Sistema de aquecimento de sangue/flui-

dos Ranger

Manual do utilizador

Ranger bloed/vloeistofverwarming

Gebruiksaanwijzing

Ranger Blod-/Væskeopvarmning

Brugsanvisning

Ranger blod-/vätskeuppvärmning

Användarhandbok

Ranger-blod/væskevarming

Bruksanvisning

Ranger veren/nesteen lämmitin

Käyttäjän opas

Θέρμανση αίματος/υγρών Ranger

∂Á¯ÂÈÚ›‰ÈÔ ÃÂÈÚÈÛÙ‹

Ranger

血液/輸液加温

取扱説明書

Urządzenie do ogrzewania krwi/płynów 

Ranger

Instrukcja Obsługi

Ranger vér-/folyadékmelegítő

Használati Utasítás

Ohřívání krve a kapalin - Ranger

Návod k obsluze

„Ranger“ kraujo/skysčio šildymas

Vartotojo vadovas

Ranger Подогрев крови/жидкости

Руководство оператора

Ranger

血液(液体)升温

操作员手册

Oper

ato

r’s

 

M

anu

al

Ranger 

Blood/Fluid Warming

Check the Ranger system website to ensure you have the most recent version of this document.      www.rangerfluidwarming.com

                            

reorder #241434C

Summary of Contents for Ranger 245

Page 1: ...ng Användarhandbok Ranger blod væskevarming Bruksanvisning Ranger veren nesteen lämmitin Käyttäjän opas Θέρμανση αίματος υγρών Ranger Á ÂÈÚ ÈÔ ÃÂÈÚÈÛÙ Ranger血液 輸液加温 取扱説明書 Urządzenie do ogrzewania krwi płynów Ranger Instrukcja Obsługi Ranger vér folyadékmelegítő Használati Utasítás Ohřívání krve a kapalin Ranger Návod k obsluze Ranger kraujo skysčio šildymas Vartotojo vadovas Ranger Подогрев крови ...

Page 2: ...sch 17 Français 33 Italiano 49 Español 65 Português 81 Nederlands 97 Dansk 113 Svenska 129 Norsk 145 Suomi 161 Ελληνικά 177 日本語 193 Polski 209 Magyar 225 Cesky 241 Lietuviškai 257 Русский 273 中文 285 Operator s Manual ...

Page 3: ...ption 4 The Ranger warming unit 4 Ranger disposable set 5 Product safety features 6 Instructions for Use 8 Preparation and setup of the Ranger warming unit 8 Removing the disposable set from the Ranger warming unit 9 Transferring the disposable set from one Ranger warming unit to another 9 Troubleshooting 10 Maintenance and Storage 12 Specifications 14 Definition of Symbols 15 ...

Page 4: ...urn a device to Arizant Healthcare Inc for service first obtain a Return Authorization RA number from a customer service representative Please use the RA number on all correspondence when returning a device for service A shipping carton will be delivered to you at no charge if needed We will service and ship your device within five 5 working days of our receipt Call your local supplier or sales re...

Page 5: ...ing unit Indications for use The Ranger warming system is intended to warm blood blood products and liquids Warnings and Cautions warning Electrical shock hazard Do not open the warming unit case Do not substitute other devices i e model 247 for the Ranger blood fluid warming unit or Ranger blood fluid disposable sets Thermal or electrical injury or device damage may occur Do not continue use of t...

Page 6: ...nit makes it easy to transport Located on the front panel you will find Alphanumeric display that indicates the heater temperature during normal operation In an over temperature condition the display alternately flashes a temperature of 43 C or higher and the word HI In an under temperature condition the display alternately flashes a temperature of 33 C or lower and word the LO Alarm indicator lig...

Page 7: ...micron filter located in a central drip chamber Disposable irrigation sets deliver 30 L hr flow rates and 142 ml priming volume They include spike sets and a 183 cm patient line Refer to the instructions provided with each disposable set for information on use Warming Cassette Flow Rate Priming Volume Patient Line Length Standard Flow Set 150 ml mn 39 44 ml 76 cm 152 cm 76 cm patient line plus 76 ...

Page 8: ...ter temperature rose to 43 C because of transient conditions Observe alphanumeric display If temperature does not drop to 41 C may take a few minutes discontinue use of unit Call Arizant Healthcare Customer Service Under temperature alarm 33 C Alarm indicator light illuminates and alarm sounds alphanumeric display alternately flashes a temperature of 33 C or lower and the word LO Heater temperatur...

Page 9: ...ety alarm 44 C Alarm indicator light illuminates and alarm sounds alphanumeric display alternately flashes a temperature of 43 C or higher and the word HI Alphanumeric display is dark alarm sounds backup safety alarm still works even if display is dark Heater temperature rose to 44 C Safety backup system is activated at 44 C and unit shuts off power to the heating plates TURN OFF THE UNIT AND UNPL...

Page 10: ...site trauma Slide the fluid warming cassette into the slot in the 2 warming unit The cassette can only fit into the device one way Prime the disposable set For more information about 3 priming the set refer to instructions provided with the disposable sets Place the bubble trap in the holder 4 Plug the power cord into an appropriate outlet Turn the 5 unit ON In a few seconds the alphanumeric displ...

Page 11: ...e from the warming unit and discard according to institutional 4 protocol Reconnect the patient IV line to the fluid source to continue the infusion without warming 5 Transferring the disposable set from one Ranger warming unit to another Follow steps 1 3 above then remove the disposable set from the first warming unit 1 During transport keep the clamps closed and do not infuse fluids while the wa...

Page 12: ... ml min to stop flow Unit was turned on and reached set point temperature before warming cassette was inserted Fluids were prewarmed to above 42 C before being run through the warming unit Open flow to reduce temperature Alarms will stop when the display reads 41 C The unit is ready to use Alarms will stop when the display reads 41 C The unit is ready to use Turn off unit Discontinue infusion of f...

Page 13: ...amp is open proximal to the warming cassette Make sure fluid is drained from warming cassette before sliding out the cassette that fluids are no longer infusing and that clamp is closed proximal to the warming cassette Warming unit is below patient level creating excessive back pressure Raise unit above patient level Condition Cause Solution Alarm indicator light illuminates and alarm sounds alpha...

Page 14: ... soapy water nonabrasive cleaning solutions dilute 2 bleach or cold sterilants Do not use abrasive materials Wipe with a dry soft cloth 3 to clean the heating plates The Ranger blood fluid hardware cleaning tool is intended to clean both heating plates of the warming unit It is not necessary to disassemble the warming unit to use the tool caution Do not insert metallic instruments in the warming u...

Page 15: ...he slot of the warming unit and 1 let sit for 15 20 minutes Clean the unit by using the cleaning tool 2 Note If the cleaning tool cannot be inserted through the slot of the warming unit because of excess dried on fluids send the unit to a biomedical technician Storage Store all components in a cool dry place when not in use Servicing There are no user serviceable parts in the Ranger warming unit A...

Page 16: ...ical hazards only in accordance with UL 2601 1 and in accordance with Canadian CSA C22 2 No 601 1 Leakage current Meets leakage current requirements in accordance with UL 60601 1 and IEC 601 1 Environmental conditions operating temperature range 15 to 40 C 59 to 104 F storage temperature range 20 to 45 C 4 to 113 F operating humidity 10 to 85 RH noncondensing atmospheric pressure range 50 kPa to 1...

Page 17: ...Warming English 15 Definition of Symbols ON OFF Fuse Attention Read accompanying documents Type B Applied Part Voltage Alternating Current AC Equipotentiality plug ground Special Refuse discard separately Protective earth ground ...

Reviews: