2.3 Stove placement/clearance requirements
Hearth and Wooden floor protection
The product must be installed on a level surface with adequate load-bearing capacity. If an existing
construction does not meet this requirement then suitable measures, e.g. load distribution plate, have to
be taken to achieve it.
The product can be placed directly on a wooden floor that is covered by a metal plate or other suitable,
non-inflammable material. The recommended minimum thickness is 12 mm.
Any flooring made of combustible material, such as linoleum, carpets, etc. must be removed
from under the floor plate. Requirement for protecting combustible flooring in front of fireplace.
The dimensions of the heart must be in accordance with national laws and regulations.
See
figure 2
Contact your local building authority regarding restrictions and installation requirements.
Walls protection
Note! The side load door must not be used in corner installations if this product is with side load
door.
Distance to wall made of combustible materialsee
figure 2
The fireplace is authorised for use with the distances to the wall of flammable material as shown in
figure 2.
A heat shield for the back can be ordered and mounted dependingon the position of the fireplace and
the desired distance tocombustible materials. See fig. 2.