background image

 

 

2.8 Permanent Air Vent Extractor Fan 

Permanent Air Vent 

 

The  stove  requires  an  adequate  air  supply  in  order  for  it  to  operate  safely  and 
efficiently.    The installer may have fitted a permanent air supply vent into the room 
in which the stove is installed to provide combustion and/or ventilation air. 

  This air 

vent should not under any circumstances be shut off or sealed.   

Extractor Fan 

 

There  must  not  be  an  extractor  fan  fitted  in  the  same  room  as  the  stove  as  this 
can cause the stove to emit smoke and fumes into the room.   

2.9 Commissioning & Handover   

On completion of the installation allow a suitable  period of time for any fire cement 
and mortar to dry out, when a small fire may be lit and checked to ensure the smoke 
and  fumes  are  taken  from  the  stove  up  the  chimney  and  emitted  safely  to  the 
atmosphere. 

Do not run at full output for at least 24 hours.   

 

On  completion  of  the  installation  and  commissioning  ensure  that  the  operating 
instructions for the stove are left with the customer. Ensure to advise the customer on 
the correct use of the appliance with the fuels likely to be used on the stove and warn 
them to use only the recommended fuels for the stove.   

 

Advise  the  user  what  to  do  should  smoke  or  fumes  be  emitted  from  the  stove.  The 
customer should be warned to use a fire guard to BS 6539 in the presence of children, 
aged and/or infirm persons 

2.10 Location   

There are several conditions to be considered in selecting a location for your stove.   

A.

 

This product is designed to be installed into a fire place. 
   

B. Allowances for proper clearances to combustibles.   

2.11 Clearance to Combustibles   

This  appliance  must  be  installed  in  a  recess,  the  recess  should  not  contain  any 
combustible  materials.  Wooden  battens  and  plaster  board  should  not  be  used  within 
the  clearance  to  combustibles.  The  minimum  clearance  to  combustibles  required  is 
550mm  to  the  top,  350mm  to  the  sides,  550mm  directly  to  the  front  and  350mm  to 
any combustible flooring.   

Summary of Contents for Tucson

Page 1: ...Introductions for Installation and Use Tucson Inset Stove Imported and Distributed by Micon Distribution Ltd 1a Hallstown Road Ballinderry Upper Lisburn BT28 2NE Arizona brand exclusively owned by Micon ...

Page 2: ...tructions 2 6 Down Draughts 2 7 Ventilation Combustion Air Requirements 2 8 Permanent Air Vent Extractor Fan 2 9 Commissioning Handover 2 10 Location 2 11 Clearance to Combustibles 2 12 Floor Protection 3 User Manual 3 1 Choice of fuel 3 2 Use 3 2 1 Use with wood 3 2 2 Use with solid fuel 3 2 3 Ash Removal 3 3 Maintenance 3 3 1 Cleaning glass 3 3 2 External surface cleaning 3 3 3 Gaskets 3 4 Opera...

Page 3: ...me plate of heat resistant material is affixed to the product This contains information about identification and documentation for the product Installation Introduction with Technical Data 1 Technical data Material Cast iron Finish High temp Resistance paint Fuel Multi fuel Log length max 30cm Flue outlet Top rear Flue pipe dimension Inside 150 mm 175 cm2 cross section Approx weight 74 5kgs Wood l...

Page 4: ...olts provided found inside the stove We recommend that two people perform the assembly and installation procedure 2 2 Installing this Stove The stove and chimney installations MUST comply with all current National and Local Building Regulations your approved dealer or your local building control officer can advise regarding this Ultimately it is you and your installer who is responsible that the i...

Page 5: ...ve the 4 fixings allowing the insert stove to be removed from the external casing 2 4 Chimney THIS PRODUCT IS SUITABLE FOR CHIMNEY INSTALLATION ONLY The stove is a radiant room heater and must be connected to a chimney of the proper size and type The chimney must have a cross sectional area of at least 124cm2 or a diameter of at least 150mm Never connect to a smaller size chimney Do not connect to...

Page 6: ...be level as the insert fire is screw fixed to the floor Step 3 Lay the external casing into the opening and position so that the front edge protrudes 20mm past the front edge of the opening Step 4 Mark the drill location and drill the holes using a 5 5mm drill bit Fix the casing to the floor using the self tapping screws provided Step 5 Lift the stove into the external casing Remove all internal p...

Page 7: ...provided It may be necessary to cut a prop to hold the spigot in place while the fixings are being attached Step 10 Complete the installation of the flexi line at the top of the chimney in accordance with the manufacturers instructions Step 11 Fit the individual components in the following order 1 Back Bricks 2 Grate Support 3 Grate 4 Loose Baffle 5 Side Bricks 6 Fire Fence 1 Back Bricks Lay the s...

Page 8: ...fle 5 Side Bricks Lay the side and back bricks in as shown 6 Fire Fence Lay the fire fence into the slots provided ensuring that they slope from front to back so that no embers can fall out through the fire fence There should be no unauthorized modification of the appliance Use only replacement parts recommended by the manufacturer 2 6 Down Draughts However well designed constructed and positioned...

Page 9: ...m An air vent outside the building should not be located less than the dimensions specified within the Building Regulations and B S 8303 Part 1 from any part of any flue terminal These air vents must also be satisfactorily fire proofed as per Building Regulations and B S 8303 Part 1 Air vents in internal walls should not communicate with bedrooms bedsits toilets bathrooms or rooms containing a sho...

Page 10: ...of the installation and commissioning ensure that the operating instructions for the stove are left with the customer Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user what to do should smoke or fumes be emitted from the stove The customer should be warned to ...

Page 11: ...ce to the top of the stove The distance the mantle protrudes past the 100mm should be added to the clearance For example if the mantle protrudes 200mm the clearance to the mantle should be 650mm See Fig6 If there is a studded wall surrounding the fireplace as in Fig 6 ensure the clearances in this Fig are adhered to ...

Page 12: ...re tested with wood with a moisture content of 16 4 Hardwood has a higher calorific value as the same valume oak ash maple birch elm beech etc Pieces of wood with a diameter greater than 10 cm should always be chopped The pieces of wood should be short enough to be able to lie flat over the layer of embers with air at both ends The maximum length of fuel in the stove no more than 40cm Recommended ...

Page 13: ...first few times it is used This must be wiped off to prevent permanent stains forming when the surface heats up Air Control What you do the National and local laws and building regulations must be followed Figure 8 The amount of heat emitted by the stove is regulated using two air controls The primary air supply where air passes up through the riddling grate is controlled using the lower air contr...

Page 14: ...stoking a lot of smoke is created which in the worst case may cause an explosive ignition of the gasses resulting in damage to the stove In order to ignite the gases that are released from the wood and to keep clear lasting flames during the combustion process it is important to let in the required quantity of oxygen air supply at all times The setting of the air supply the method of ignition and ...

Page 15: ...ave the lower control open for a few minutes to allow the initial volatiles in the fuel to burn Adjust the lower control to the desired position Very Important The stove door should never be opened when the stove is being fired vigorously Warning The firebox and ashpit cover shall be kept closed except during ignition refueling and removal of residue material We would strongly recommend that you d...

Page 16: ...to put out ashpan It is essential to keep the grate free from a heavy build up of ashes This product is equipped with a grate riddling device which is used to shake ashes off the grate into the ash pan Whenever the stove is burning without life when the lower control is open use the riddling lever to clear the grate of surplus ashes If burning solid fuel always empty the ash pan at least once a da...

Page 17: ...ly the painted surface may assume a greyish tinge over time but the stove can easily be freshened up with spray paint which is available from your local retailer 3 3 3 Gaskets The gaskets in the door will wear out over time and should be replaced as required in order to prevent runaway combustion 3 4 Operational Problems Troubleshooting Problem Probable causes Action Fire difficult to start Fire g...

Page 18: ...n houses equipped with mechanical ventilation open a window until the fire is well established Smokes while burning Draught is insufficien Down draught Room is in decompression Consult a chimney specialist Check that the flue is not obstructed sweep if necessary Install an anti down draught cowl Consult your Dealer In houses equipped with Mechanical Ventilation an outside air intake must be instal...

Reviews: