background image

 

 

To  remove  the  loose  baffle,  lift  the  front  edge  until  it  hits  the  top  and  then  slide  it 
forward.    Then  drop  the  rear  edge  and  the  baffle  will  slide  down.    To  remove  the 
fixed baffle, loosen the two screws and slide it 
forwards, it will then drop down.   

To  remove  the  cast  iron  liners,  lift  them  clear 
of  the  grate  support  plate  and  then  move  the 
front edge of the casting towards the middle of 
the  stove,  and  clear  of  the  back  wall  of  the 
stove,  then  tilt  the  casting  so  that  it  can  be 
removed  diagonally  through  the  opening. 
Remove the flue spigot and gasket by removing 
the four bolts.   

Next,  remove  the  grate  by  pushing  it  from 
underneath,  the  riddling  bar  is  not  fixed  to  the 
grate. This will allow access to four M6 fixings 
which will attach the stove to the outer casing. 
Remove the 4 fixings, allowing the insert stove 
to be removed from the external casing.   

2.4 Chimney   

THIS  PRODUCT  IS  SUITABLE  FOR 
CHIMNEY INSTALLATION ONLY

.   

The  stove  is  a  radiant  room  heater  and  must 
be  connected  to  a  chimney  of  the  proper  size 
and  type.  The  chimney  must  have  a  cross 
sectional area of at least 124cm

2

 

or a diameter 

of at least 150mm. Never connect to a smaller 
size  chimney.  Do  not  connect  to  a  chimney 
serving another appliance. Minimum chimney 
height 4.5 meters from floor on which stove is 
installed.   

It is recommended that a flue liner of diameter 
150mm be used to line the chimney, the liner 
should  be  approved  for  use  with  solid  fuel. 
See Fig. 1.   

It is permitted to connect using a closure plate 
and  a  connection  piece  from  the  stove  to  the 
closure  plate  (See  Fig  2),  provided  that  the 
chimney  is  of  sound  construction  with  no 
leaks or cracks, a clay flue liner has been used 

that can withstand up to 1000

o

C, the clay liner has a diameter no greater than 200mm.   

Summary of Contents for Tucson

Page 1: ...Introductions for Installation and Use Tucson Inset Stove Imported and Distributed by Micon Distribution Ltd 1a Hallstown Road Ballinderry Upper Lisburn BT28 2NE Arizona brand exclusively owned by Micon ...

Page 2: ...tructions 2 6 Down Draughts 2 7 Ventilation Combustion Air Requirements 2 8 Permanent Air Vent Extractor Fan 2 9 Commissioning Handover 2 10 Location 2 11 Clearance to Combustibles 2 12 Floor Protection 3 User Manual 3 1 Choice of fuel 3 2 Use 3 2 1 Use with wood 3 2 2 Use with solid fuel 3 2 3 Ash Removal 3 3 Maintenance 3 3 1 Cleaning glass 3 3 2 External surface cleaning 3 3 3 Gaskets 3 4 Opera...

Page 3: ...me plate of heat resistant material is affixed to the product This contains information about identification and documentation for the product Installation Introduction with Technical Data 1 Technical data Material Cast iron Finish High temp Resistance paint Fuel Multi fuel Log length max 30cm Flue outlet Top rear Flue pipe dimension Inside 150 mm 175 cm2 cross section Approx weight 74 5kgs Wood l...

Page 4: ...olts provided found inside the stove We recommend that two people perform the assembly and installation procedure 2 2 Installing this Stove The stove and chimney installations MUST comply with all current National and Local Building Regulations your approved dealer or your local building control officer can advise regarding this Ultimately it is you and your installer who is responsible that the i...

Page 5: ...ve the 4 fixings allowing the insert stove to be removed from the external casing 2 4 Chimney THIS PRODUCT IS SUITABLE FOR CHIMNEY INSTALLATION ONLY The stove is a radiant room heater and must be connected to a chimney of the proper size and type The chimney must have a cross sectional area of at least 124cm2 or a diameter of at least 150mm Never connect to a smaller size chimney Do not connect to...

Page 6: ...be level as the insert fire is screw fixed to the floor Step 3 Lay the external casing into the opening and position so that the front edge protrudes 20mm past the front edge of the opening Step 4 Mark the drill location and drill the holes using a 5 5mm drill bit Fix the casing to the floor using the self tapping screws provided Step 5 Lift the stove into the external casing Remove all internal p...

Page 7: ...provided It may be necessary to cut a prop to hold the spigot in place while the fixings are being attached Step 10 Complete the installation of the flexi line at the top of the chimney in accordance with the manufacturers instructions Step 11 Fit the individual components in the following order 1 Back Bricks 2 Grate Support 3 Grate 4 Loose Baffle 5 Side Bricks 6 Fire Fence 1 Back Bricks Lay the s...

Page 8: ...fle 5 Side Bricks Lay the side and back bricks in as shown 6 Fire Fence Lay the fire fence into the slots provided ensuring that they slope from front to back so that no embers can fall out through the fire fence There should be no unauthorized modification of the appliance Use only replacement parts recommended by the manufacturer 2 6 Down Draughts However well designed constructed and positioned...

Page 9: ...m An air vent outside the building should not be located less than the dimensions specified within the Building Regulations and B S 8303 Part 1 from any part of any flue terminal These air vents must also be satisfactorily fire proofed as per Building Regulations and B S 8303 Part 1 Air vents in internal walls should not communicate with bedrooms bedsits toilets bathrooms or rooms containing a sho...

Page 10: ...of the installation and commissioning ensure that the operating instructions for the stove are left with the customer Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user what to do should smoke or fumes be emitted from the stove The customer should be warned to ...

Page 11: ...ce to the top of the stove The distance the mantle protrudes past the 100mm should be added to the clearance For example if the mantle protrudes 200mm the clearance to the mantle should be 650mm See Fig6 If there is a studded wall surrounding the fireplace as in Fig 6 ensure the clearances in this Fig are adhered to ...

Page 12: ...re tested with wood with a moisture content of 16 4 Hardwood has a higher calorific value as the same valume oak ash maple birch elm beech etc Pieces of wood with a diameter greater than 10 cm should always be chopped The pieces of wood should be short enough to be able to lie flat over the layer of embers with air at both ends The maximum length of fuel in the stove no more than 40cm Recommended ...

Page 13: ...first few times it is used This must be wiped off to prevent permanent stains forming when the surface heats up Air Control What you do the National and local laws and building regulations must be followed Figure 8 The amount of heat emitted by the stove is regulated using two air controls The primary air supply where air passes up through the riddling grate is controlled using the lower air contr...

Page 14: ...stoking a lot of smoke is created which in the worst case may cause an explosive ignition of the gasses resulting in damage to the stove In order to ignite the gases that are released from the wood and to keep clear lasting flames during the combustion process it is important to let in the required quantity of oxygen air supply at all times The setting of the air supply the method of ignition and ...

Page 15: ...ave the lower control open for a few minutes to allow the initial volatiles in the fuel to burn Adjust the lower control to the desired position Very Important The stove door should never be opened when the stove is being fired vigorously Warning The firebox and ashpit cover shall be kept closed except during ignition refueling and removal of residue material We would strongly recommend that you d...

Page 16: ...to put out ashpan It is essential to keep the grate free from a heavy build up of ashes This product is equipped with a grate riddling device which is used to shake ashes off the grate into the ash pan Whenever the stove is burning without life when the lower control is open use the riddling lever to clear the grate of surplus ashes If burning solid fuel always empty the ash pan at least once a da...

Page 17: ...ly the painted surface may assume a greyish tinge over time but the stove can easily be freshened up with spray paint which is available from your local retailer 3 3 3 Gaskets The gaskets in the door will wear out over time and should be replaced as required in order to prevent runaway combustion 3 4 Operational Problems Troubleshooting Problem Probable causes Action Fire difficult to start Fire g...

Page 18: ...n houses equipped with mechanical ventilation open a window until the fire is well established Smokes while burning Draught is insufficien Down draught Room is in decompression Consult a chimney specialist Check that the flue is not obstructed sweep if necessary Install an anti down draught cowl Consult your Dealer In houses equipped with Mechanical Ventilation an outside air intake must be instal...

Reviews: