background image

18

Label on the Sling

Care and Washing Symbols

Machine wash 70°C (158°F)

No bleaching allowed

No tumble drying allowed

Tumble drying
Does not apply to Flites

No ironing allowed

Do NOT wash the Flites
Only applies to Flites

No dry cleaning allowed

Certifi cates/Markings

CE marking in accordance with the 
Medical Devices Directive 93/42/EEC. 
The equipment has been tested and 
ful

¿

 ls all essential requirements.

Flites Symbols

PATIENT SPECIFIC

DISPOSABLE SLING

Only on Flites. (Disposable and patient 
speci

¿

 c)

“Do NOT wash” symbol. Located on the 
outside of the sling.

“Do NOT use/lift” symbol. The Flites has 
been washed. Located on the outside of 
the sling.

Symbol for Loop

Use a loop spreader bar.

Article Number

REF 
XXXXXX-X

Article number with -X refers to 
the sling size. 

REF 
XXXXXXX

If the article number is stated 
without the size letter at the end, 
it means the sling is a One Size.

Fibre Content

PES

Polyester

PE

Polyethylene

PP

Polypropylene

Misc. Symbols

Safe Working Load (SWL)

Patient’s name symbol

Record symbol

Read the 

IFU

 before use

REF

Article number

Manufacturing date and year

Manufacturer name and address

EN

Summary of Contents for MLAAS2000

Page 1: ...INSTRUCTIONS FOR USE Passive Loop Slings 04 SL 00 7ENAU 08 2019...

Page 2: ...tions may cause damage to all or parts of the system or equipment NOTE Means This is important information for the correct use of this system or equipment Contents Foreword 2 Customer Support 2 De nit...

Page 3: ...mself herself at all Cannot stand unsupported and is not able to bear weight not even partially Dependent on caregiver in most situations Physically demanding for caregiver Stimulation of remaining ab...

Page 4: ...ed over a small surface area when compared to lying in bed An individualised skin and holistic assessment of the patient should be undertaken before deciding on whether a sling should be left under a...

Page 5: ...Shoulder strap with loops 5 Leg strap with loop 6 Leg ap 7 Body section 8 Pulling handle 9 Head section 10 Flites Do NOT wash use lift label located on the outside of the sling 11 Padding 12 Leg stif...

Page 6: ...nfection instructions in this IFU 4 Check that the sling is clean If the sling is not clean see Cleaning and Disinfection on page 14 5 Always check the washing symbol on the Flites label If the Flites...

Page 7: ...Head Support intended to be seated on S M L XL MLA3000 272 kg 600 lb Standard padded low back quick t S M L XL MFA2100 272 kg 600 lb Flites with head support Disposable and Patient Speci c S M L XL X...

Page 8: ...MLA2000 272 kg 600 lb S M S M L XL S M L XL M L XL S M L XL MLA2000A 272 kg 600 lb M M L XL M L XL M L XL M L XL MLAAS2000 190 kg 418 lb S M S M L XL S M L XL M L XL S M L XL MLA4060 272 kg 600 lb S M...

Page 9: ...next page Loop Attachment Detachment 2 point spreader bar First attach the shoulder loops then attach the leg loops 4 point spreader bar First attach the shoulder loops in the front hooks Then attach...

Page 10: ...according to the lift IFU In Chair Wheelchair 20 steps 1 Place the lift nearby 2 Apply the brakes on the wheelchair 3 Check that the stiffeners are completely inside the stiffener pockets if any 4 St...

Page 11: ...nue to step 18 9 Patient not able to sit up Fold the sling lengthwise along the centre line outside facing outside The sling label is located on the outside 10 Log roll the patient Use local technique...

Page 12: ...ess 30 Make sure that All loops are securely attached All straps are straight not twisted The patient lays comfortably in the sling 31 If an adjustment is needed lower the patient and make sure that t...

Page 13: ...Fig 18 Removing the Sling In Bed 13 steps 1 Position the patient over the bed See Fig 16 2 Apply bed brakes and adjust the height of the bed to an ergonomic position if possible WARNING To avoid inju...

Page 14: ...158 F In order to obtain suf cient level of disinfection please wash according to local hygiene legislation If allowed according to the product label tumble dry in low temperature max 60 C 140 F 6 Do...

Page 15: ...ort is intact If damaged or missing and the underlying red Do NOT use lift symbol appears replace the sling immediately See Label on the Sling on page 18 When Soiled Stained and Between Patients Clean...

Page 16: ...patient s neck back outside of the sling Raise the back rest of the bed if available Adjust the spreader bar to a more reclined position Pay attention to the patient s head There are dif culties appl...

Page 17: ...0 C 68 F Operating and Storage 10 95 at 20 C 68 F Transport Recycling The device should be recycled according to national regulations Package The bag consists of soft plastic recyclable to local legis...

Page 18: ...G Only on Flites Disposable and patient speci c Do NOT wash symbol Located on the outside of the sling Do NOT use lift symbol The Flites has been washed Located on the outside of the sling Symbol for...

Page 19: ...9 0 6 87426222 E mail Italy promo arjo com MIDDLE EAST Arjo Middle East FZ LLC Of ce 908 9th Floor HQ Building North Tower Dubai Science Park Al Barsha South P O Box 11488 Dubai United Arab Emirates D...

Page 20: ...rgonomic patient handling personal hygiene disinfection diagnostics and the effective prevention of pressure ulcers and venous thromboembolism we help professionals across care environments to continu...

Reviews: