Before First Use (6 steps)

1.  Check all parts of the sling, see section 

“Parts

Designation” on page 5

. If any part is missing 

or damaged - Do NOT use the sling.

2. Read this 

IFU

 thoroughly.

3.  Check that the sling is clean.
4.  Choose a designated area where the 

IFU

 should 

be kept and easily accessible at all times.

5.  Make sure to have a rescue plan ready in case of 

a patient emergency.

6.  For questions, contact your local Arjo 

representative for support.

NOTE

Arjo recommends the name of the patient is 
written on the sling care label to avoid cross 
contamination between patient s.

Before Every Use (7 steps)

1.  Patient assessment must always determine the 

methods used in everyday care, see 

“Intended

Use” on page 3

.

WARNING

To avoid the patient from falling, make sure 
to select the correct sling size according to 
the

IFU

.

2.  Check the allowed combinations against the sling, 

spreader bar and lift, see 

“Allowed Combinations” 

on page 7

.

WARNING

To avoid injury, always make sure to inspect 
the equipment prior to use.

3.  Check all parts of the sling, see 

“Parts

Designation” on page 5

. If any part is missing 

or damaged - Do NOT use the sling. Check for: 
• fraying
• loose 

stitching

• tears
• fabric 

holes

• soiled 

fabric

• damaged 

loops

•  unreadable or damaged label

WARNING

To prevent cross-contamination, always 
follow the disinfection instructions in this 

IFU

.

4.  Check that the sling is clean. If the sling is 

not clean see

”Cleaning and Disinfection” on 

page 14

5.  Always check the washing symbol on the Flites 

label. If the Flites has been washed, throw the 
Flites away. See 

“Flites – Do NOT wash” on 

page 14.

6. 

If this symbol appears, do NOT use the 
Flites. The Flites label indicates it has 
been washed. 
7. 

Before using the 

sling, read the lift 

IFU

 for transfer, transport and 

bathing.

After every use

If the patient is leaving the hospital, throw away the 
patient speci

¿

 c Flites.

Select Sling Size

Using the Arjo Measuring Tape (4 
steps) (Accessory)

The Arjo Measuring Tape is a sizing accessory 
only intended as a guide and is an approximation. 
Patient width and body proportions should also be 
considered when selecting the correct size of Arjo 
sling.
1.  If possible, the patient should be in a seated 

position.

2.  Place the point marked 

A

 on the measuring tape 

over the patient ’s coccyx/against seat (position 

A

). 

(See Fig. 1 ) and (See Fig. 2 )

3.  

Measure from coccyx/seat (position 

A

) to the top 

of the head (position 

B

(See Fig. 1 ).

4.  

The coloured area on the measuring tape that 
is levelled with the top of the patient ’s head 
indicates the required sling size. If the sling size 
falls in between two sizes, it is recommended to 
select the smaller size. 

(See Fig. 2 )

Sizing Without a Measuring Tape 
(2 steps)

1.  Place the sling over the patient ’s back.
2.  Make sure the sling covers the patient from 

the top of the head (position 

B

) to the coccyx 

(position 

A

). 

(See Fig. 1 )

EN

Summary of Contents for MLAAS2000

Page 1: ...INSTRUCTIONS FOR USE Passive Loop Slings 04 SL 00 7ENAU 08 2019...

Page 2: ...tions may cause damage to all or parts of the system or equipment NOTE Means This is important information for the correct use of this system or equipment Contents Foreword 2 Customer Support 2 De nit...

Page 3: ...mself herself at all Cannot stand unsupported and is not able to bear weight not even partially Dependent on caregiver in most situations Physically demanding for caregiver Stimulation of remaining ab...

Page 4: ...ed over a small surface area when compared to lying in bed An individualised skin and holistic assessment of the patient should be undertaken before deciding on whether a sling should be left under a...

Page 5: ...Shoulder strap with loops 5 Leg strap with loop 6 Leg ap 7 Body section 8 Pulling handle 9 Head section 10 Flites Do NOT wash use lift label located on the outside of the sling 11 Padding 12 Leg stif...

Page 6: ...nfection instructions in this IFU 4 Check that the sling is clean If the sling is not clean see Cleaning and Disinfection on page 14 5 Always check the washing symbol on the Flites label If the Flites...

Page 7: ...Head Support intended to be seated on S M L XL MLA3000 272 kg 600 lb Standard padded low back quick t S M L XL MFA2100 272 kg 600 lb Flites with head support Disposable and Patient Speci c S M L XL X...

Page 8: ...MLA2000 272 kg 600 lb S M S M L XL S M L XL M L XL S M L XL MLA2000A 272 kg 600 lb M M L XL M L XL M L XL M L XL MLAAS2000 190 kg 418 lb S M S M L XL S M L XL M L XL S M L XL MLA4060 272 kg 600 lb S M...

Page 9: ...next page Loop Attachment Detachment 2 point spreader bar First attach the shoulder loops then attach the leg loops 4 point spreader bar First attach the shoulder loops in the front hooks Then attach...

Page 10: ...according to the lift IFU In Chair Wheelchair 20 steps 1 Place the lift nearby 2 Apply the brakes on the wheelchair 3 Check that the stiffeners are completely inside the stiffener pockets if any 4 St...

Page 11: ...nue to step 18 9 Patient not able to sit up Fold the sling lengthwise along the centre line outside facing outside The sling label is located on the outside 10 Log roll the patient Use local technique...

Page 12: ...ess 30 Make sure that All loops are securely attached All straps are straight not twisted The patient lays comfortably in the sling 31 If an adjustment is needed lower the patient and make sure that t...

Page 13: ...Fig 18 Removing the Sling In Bed 13 steps 1 Position the patient over the bed See Fig 16 2 Apply bed brakes and adjust the height of the bed to an ergonomic position if possible WARNING To avoid inju...

Page 14: ...158 F In order to obtain suf cient level of disinfection please wash according to local hygiene legislation If allowed according to the product label tumble dry in low temperature max 60 C 140 F 6 Do...

Page 15: ...ort is intact If damaged or missing and the underlying red Do NOT use lift symbol appears replace the sling immediately See Label on the Sling on page 18 When Soiled Stained and Between Patients Clean...

Page 16: ...patient s neck back outside of the sling Raise the back rest of the bed if available Adjust the spreader bar to a more reclined position Pay attention to the patient s head There are dif culties appl...

Page 17: ...0 C 68 F Operating and Storage 10 95 at 20 C 68 F Transport Recycling The device should be recycled according to national regulations Package The bag consists of soft plastic recyclable to local legis...

Page 18: ...G Only on Flites Disposable and patient speci c Do NOT wash symbol Located on the outside of the sling Do NOT use lift symbol The Flites has been washed Located on the outside of the sling Symbol for...

Page 19: ...9 0 6 87426222 E mail Italy promo arjo com MIDDLE EAST Arjo Middle East FZ LLC Of ce 908 9th Floor HQ Building North Tower Dubai Science Park Al Barsha South P O Box 11488 Dubai United Arab Emirates D...

Page 20: ...rgonomic patient handling personal hygiene disinfection diagnostics and the effective prevention of pressure ulcers and venous thromboembolism we help professionals across care environments to continu...

Reviews: