background image

. H009$

LEAD DIGIT SEND

. H008$

DISABLE

. H007$

ENABLE

. H012$

CHECK DIGIT NO SEND

. H010$

LEAD DIGIT NO SEND

. H011$

CHECK DIGIT SEND

. H037$

+5 ON

. H038$

+ 5 OFF

. H039$

+2 ON

. H040$

+ 2 OFF

. H047$

ADD A SPACE ON

. H048$

ADD A SPACE OFF

. H055$

ADDENDA REQUIRED OFF

. H056$

ADDENDA REQUIRED ON

GROUP-31

SYMBOLOGIES FORMATTING: UPC-E

UPC-E

ADD ON SUPPLEMENT

If ADDENDA REQUIRED is set to ON, the scanner
will only read an UPC-E bar code that has an addenda.
At the same time please also scan +5 ON or +2 ON so
the scanner will output a 5-digit or 2-digit addendum.

NOTE:

Summary of Contents for AS500

Page 1: ...Version 2017 1 Ez One Shot WIRELESS RING BARCODE SCANNER USER S MANUAL ...

Page 2: ... Default table Appendix 2 Barcode test chart 9 LED Beeper Indication 6 Reading Mode Button Illumination Preference 8 7 4 5 3 2 Send Data Length Preamble Postamble 13 Interface BT HID Getting Connected BT HID Smartphone Tablet Touch Keyboard Power Off Timeout Memory Mode Memory Mode Delete Record Memory Mode Data Format Date Time Setup Memory Mode Date Format Time Format Table of Contents Cloning M...

Page 3: ...wer Off or Standby Wireless Disconnection Unexpected Barcode Scan during Configuration Memory Full Flashing Flashing 1 Flash 1 Flash 2 Flashes 1 Flash 1 Flash 1 Flash 1 Flash 3 Flashes 2 beeps 2 beeps 3 beeps Reads Configuration Barcode Barcode Scan in Memory Mode 1 beep 1 beep 3 short beeps 3 short beeps 3 short beeps 5 beeps Poor Connection Out of Range 1 Flash 4 beeps Hi Lo Hi Lo ...

Page 4: ...s are upper case 2 All cloning strings printed on labels should be the same as those on the monitor sequentially from first to last 3 Cloning mode works in Word Note Pad only 4 Never edit the data on the first row A017 It is an entry command for cloning 5 The cloning string s length can be adjusted by combining multiple strings into one or by breaking one string into multiple strings starting from...

Page 5: ...and so on sequentially top to bottom with the scanner you wish to clone these settings to A017 8C06 8D02980A A017 0604 5A02 5F04 4 4 4 4 Dot A017 06045A02 5F04 12 4 Dot A017 8C06 8D02980A A017 0604 5A02 5F04 Wrong Setting The string consists of 4 Dots located at the beginning of second row do not break the into multiple strings Wrong Setting The string lengths of the second and third row do not ma...

Page 6: ...can MIN LENGTH or MAX LENGTH Set Code ID Example Code 39 Step 1 Scan CODE 39 SET ID from Group 8 Step 2 Scan either one or two alphanumerics maximum 2 digits from Full ASCII table Group 40 46 Step 3 Scan CODE 39 SET ID from Group 8 Set Data Format Step 1 Scan DATA FORMAT Step 2 Scan 1 3 digits from Full ASCII Table Numbers Group 46 Step 3 Scan DATA FORMAT Set Field Separator Step 1 Scan FIELD SEPA...

Page 7: ...lti step configuration Caution Scanning SETUP CODE OFF will turn the scanner into unprogrammable state and the scanner will not react to any configuration barcode Caution Once disabled the scanner will output the original encoded data of the barcodes in Full ASCII Table Function Navigation Modifier Keys Group 47 49 DISABLE C020 ENABLE FUNCTION CODE CONVERSION C019 C020 C019 ...

Page 8: ...ADING MODE BUTTON PREFERENCE F064 F064 RIGHT BUTTON ONLY F065 F065 LEFT BUTTON ONLY Scan one of below configuration barcodes to determine which touch sensing button to enable according to your habit ILLUMINATION PREFERENCE F066 F066 BOTH BUTTONS Recommended for left handed user Recommended for right handed user LASER ALWAYS ON LED AUTO ADAPTIVE LASER ALWAYS ON LED ON AFTER 1 SEC F059 F059 F049 F04...

Page 9: ...r the BT HID USB HID interface the default terminator is CR 2 For the USB VCP interface the default terminator is CR LF 3 Below is the position of Terminator among output data string Preamble Symbology ID Barcode Length Barcode Data Postamble Terminator 4 By default with Preamble Postamble Barcode Length and Symbology ID disabled the scanner data output will be Barcode Data Terminator NOTES CR ...

Page 10: ...to the beginning of a scanned barcode 2 A POSTAMBLE is a string of up to 16 characters added to the end of a scanned barcode 3 Default value for both None Preamble Symbology ID Barcode Length Barcode Data Postamble Terminator Set PREAMBLE String as POSTAMBLE String as STEP 1 Scan CLEAR PRE POSTAMBLE STEP 2 Scan PREAMBLE STEP 3 Scan twice from Full ASCII Table STEP 4 Scan PREAMBLE STEP 5 Scan POSTA...

Page 11: ...The higher the number the greater the accuracy SETTING PROCEDURE 1 Scan ACCURACY ADJUSTMENT 2 Scan one digit 1 9 from barcode menu above 3 Scan ACCURACY ADJUSTMENT NOTES P023 RESET ABORT 1 The scanner will beep three times as indication that a setting is not yet complete or unexpected barcode is scanned during multi step configuration 2 If you make a mistake forget a step etc and want to abort the...

Page 12: ...NEGATIVE BARCODES D022 GROUP 6 GENERAL SETTINGS CODE ID INVERSE BARCODE ENABLE INVERSE BARCODE CODE ID SYMBOLOGY ID NOTES 1 Only ONE code ID will be sent 2 The code ID is located at the position before the barcode data and after the preamble EXAMPLE 1 Preamble 145287 2 Code ID enable AIM ID 3 Bar code symbologies EAN 13 5 4 DISABLE INVERSE BARCODE DISABLE CODE ID DATA FORMAT Preamble Symbology ID ...

Page 13: ...AN8 2 ON EAN8 5 ON UPC E 2 5 OFF UPC E 2 ON UPC E 5 ON UPC A 2 5 OFF UPC A 2 ON UPC A 5 ON EAN 13 2 5 OFF EAN 13 2 ON EAN 13 5 ON Code 93 Code 11 disable CDV Code 11 send one CD Code 11 send two CD Code 11 not send CD Databar Databar Stacked Databar Stacked Omnidirectional Databar Truncated Telepen ASCII Telepen Numeric J U L F A E S K T C1 C0 E4 E4 E4 E0 E3 E3 E0 E3 E3 E0 E3 E3 G0 H0 H0 H1 H3 B0 ...

Page 14: ...007 P021 P010 P016 P022 P009 P011 P012 P001 EAN 13 Set ID EAN 8 Set ID UPC E Set ID UPC A Set ID Code 39 Set ID Code 93 Set ID Codabar Set ID IATA Set ID Code 128 Set ID EAN 128 Set ID Telepen Set ID Code 11 Set ID Code 32 Set ID China Post Code TOSHIBA Code Set ID ...

Page 15: ...r RSS Limited Set ID GS1 Databar RSS Expanded Set ID GS1 Databar RSS Set ID LABEL Code Set ID Reserved Steps 1 Scan the SET ID bar code for a particular symbology 2 Scan one or two alphanumeric characters from the Full ASCII Table 3 Scan the SET ID bar code again 4 If you make a mistake forget a step etc and want to abort the multi step configuration scan RESET ABORT and start over from step 1 to ...

Page 16: ...GENERAL SETTINGS GROUP 10 INTERBLOCK DELAY INTERCHARACTER DELAY 0mS 10mS 50mS 100mS 200mS 500mS 140uS 500uS 1mS 4mS 16mS ...

Page 17: ...14 ITALIAN C009 JAPAN 106 key CANADIAN TRADITIONAL C034 NORWEGIAN C029 SWEDISH C026 PORTUGUESE C031 CANADIAN FRENCH C025 C016 SWISS GERMAN C017 CZECH QWERTY C022 CZECH QWERTZ HUNGARIAN QWERTZ C021 C015 ALT CODE HUNGARIAN 101 KEY C024 SWISS FRENCH C023 BRAZILIAN PORTUGUESE C033 SLOVAK C032 DANISH C027 DUTCH C028 BELGIAN AZERTY C030 ...

Page 18: ...ic key is used for trasmitting 2 If you select NUMERIC KEY the Num Lock status of the digits Scan NUMERIC KEY if you want to use the keys physical keyboard should be ON on the numeric keypad NOTE 1 By default HT I CR M and ESC A is transmitted as 0x09 0x0D and 0x1B respectively 2 When enabled HT I CR M and ESC A is transmitted as TAB ENTER and ESCAPE on keyboard respectively 2 If ABCD ABCD abcd ab...

Page 19: ...E043 Memory Mode C035 Emulates a Bluetooth HID keyboard that transmits each barcode data to the host after decode Wireless scanner operates in this mode right out of box Please see next page Group 14 for details Emulates a USB keyboard that transmits each barcode data to the host after decode Barcode data is sent via USB cable directly Emulates a USB mass storage device that saves each barcode dat...

Page 20: ...onds until the the scanner emit two beeps 2 Scan BT HID the scanner will emit two beeps 3 Scan either one of below barcodes according to your host system 4 Select Scanner XXXXXX on the discovered device list of your Bluetooth XXXXXX are the last 6 digits of MAC address which can also be found on the product label 6 The scanner will emit two beeps to verify the connection E031 E031 GETTING CONNECTE...

Page 21: ...le connected with the scanner the Touch Keyboard on the Android smartphone or tablet might disappear To resolve this issue please change settings on Android device with below steps 1 Enter Settings 2 Enter Language input 3 Tap on Default keyboard 4 Turn off Physical keyboard or Turn on On screen keyboard and the Touch Keyboard will function properly again Slideto turnoff SMARTPHONE TABLET TOUCH KE...

Page 22: ... the second and minute ranging from 10 seconds 00 10 to 60 minutes and 60 seconds 60 60 For example to set the timeout as 5 minutes 30 seconds 1 Scan Set Minute 2 Scan 0 5 on below numeric barcode table Range 00 60 Range 00 60 3 Scan Set Minute 4 Scan Set Second 5 Scan 3 0 on below numeric barcode table 6 Scan Set Second NUMERIC BARCODES 1 2 3 4 5 6 7 8 9 0 Warning This will cause the battery to d...

Page 23: ...he barcode data will be stored in the format of Date Time BarcodeData CR To retrieve stored data please connect the scanner to the host with cable access removable storage device MiniScan from which you may open or copy the file BARCODE txt to your computer To exit Memory Mode simply scan any interface barcode in INTERFACE section Group 13 To delete ALL stored data simply delete the file BARCODE t...

Page 24: ... may replace it with any alphanumeric characters from the full ASCII table Example To change Field Separator to Semicolon 1 Scan Field Separator 2 Scan from the full ASCII table Group 40 46 3 Scan Field Separator R010 FIELD SEPARATOR R011 DATA FORMAT MEMORY MODE DATE TIME SETUP Example To change Data Format to Barcode Data Date Time 1 Scan Data Format 2 Scan 4 2 3 from Group 46 3 Scan Data Format ...

Page 25: ...12 1 Scan Date Format 2 Scan 1 2 from Group 46 3 Scan Date Format Example To set Time Format to HH MM Code 02 1 Scan Time Format 2 Scan 0 2 from Group 46 3 Scan TimeFormat R008 DATE FORMAT R009 TIME FORMAT MEMORY MODE DATE FORMAT MEMORY MODE TIME FORMAT 01 02 03 04 05 06 07 08 DD MM YYYY MM DD YYYY DD MM YY MM DD YY YYYY MM DD YY MM DD DD MM MM DD Code Format Code Format 09 10 11 12 13 14 15 16 DD...

Page 26: ...NABLE ALL CODE A002 INDUSTRIAL 2 OF 5 N001 MATRIX 2 OF 5 M010 TELEPEN L014 ENABLE DISABLE SYMBOLOGIES CHINA POSTAL CODE K002 CODE 128 J011 CODABAR I 002 INTERLEAVED 2 OF 5 J002 CODE 32 K011 UK PLESSEY CODE L011 DISABLE ALL CODE A003 INDUSTRIAL 2 OF 5 N002 MATRIX 2 OF 5 M011 TELEPEN L015 ENABLE DISABLE GROUP 20 ...

Page 27: ...N 8 I 011 CODE 11 G011 CODE 93 M002 EAN 128 L002 MSI G009 CODE 39 N018 IATA ENABLE DISABLE SYMBOLOGIES H001 UPC A H007 UPC E H013 EAN 13 H019 EAN 8 I 010 CODE 11 G010 CODE 93 M001 EAN 128 L001 MSI G008 CODE 39 N017 IATA ENABLE DISABLE GROUP 21 ...

Page 28: ...LE N039 GS1 Databar LIMITED DISABLE N011 GS1 Databar EXPANDED DISABLE N027 GS1DatabarEXPANDEDSTACKEDDISABLE N029 GS1 Databar ENABLE N032 GS1 Databar STACKED ENABLE N038 GS1 Databar LIMITED ENABLE N010 GS1 Databar EXPANDED ENABLE N026 GS1DatabarEXPANDEDSTACKEDENABLE N028 ENABLE DISABLE SYMBOLOGIES CHINA POSTAL CODE ENABLE DISABLE GROUP 22 CHINA POSTAL CODE TOSHIBA CODE ...

Page 29: ...t fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology NOTES P023 RESET ABORT 1 The scanner will beep three times as indication that a setting is not yet complete or unexpected barcode is scanned during multi step configuration 2 If you make a mista...

Page 30: ...I UK PLESSEY CODE ENABLE DISABLE CDV SEND CD CDV NOT SEND CD CHECK DIGIT DOUBLE MOD 10 CHECK DIGIT DOUBLE 11 PLUS MOD 10 CHECK DIGIT SINGLE MOD 10 MIN LENGTH 6 MAX LENGTH 48 ENABLE DISABLE CDV SEND CD L001 L002 L004 L003 L007 L008 L009 L005 L006 L010 L011 L012 L013 ...

Page 31: ...t fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology NOTES P023 RESET ABORT 1 The scanner will beep three times as indication that a setting is not yet complete or unexpected barcode is scanned during multi step configuration 2 If you make a mista...

Page 32: ...24 ENABLE MIN LENGTH 6 MAX LENGTH 48 DISABLE ENABLE DISABLE DISABLE CDV ENABLE TELEPEN TELEPEN NUMBER DISABLE TELEPEN CDV NOT SEND CDV CDV SEND CD MAX LENGTH 48 MIN LENGTH 6 G010 G011 G012 G013 L014 L015 L020 L021 N017 N018 N019 N020 N021 N022 N023 TELEPEN ASCII ...

Page 33: ...t fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology NOTES P023 RESET ABORT 1 The scanner will beep three times as indication that a setting is not yet complete or unexpected barcode is scanned during multi step configuration 2 If you make a mista...

Page 34: ...J007 I 010 I 011 I 012 I 013 I 042 I 043 I 014 I 015 I 016 DISABLE CDV SEND CD CDV NOT SEND CD First digit suppressed Last digit suppressed MIN LENGTH 6 MAX LENGTH 48 ENABLE CDV SEND CD CDV SEND CD 1 DIGIT CDV SEND CD 2 DIGITS CDV NOT SEND CD MIN LENGTH 6 MAX LENGTH 32 ENABLE DISABLE CDV NO suppressed DISABLE DISABLE CDV ...

Page 35: ...t fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology NOTES P023 RESET ABORT 1 The scanner will beep three times as indication that a setting is not yet complete or unexpected barcode is scanned during multi step configuration 2 If you make a mista...

Page 36: ...TRIAL 2 OF 5 MATRIX 2 OF 5 N001 N002 N003 N004 N007 N006 N005 M010 M011 M012 M013 M016 M015 M014 DISABLE DISABLE CDV DISABLE DISABLE CDV ENABLE CDV SEND CD CDV NOT SEND CD MIN LENGTH 6 MAX LENGTH 48 ENABLE CDV SEND CD MAX LENGTH 48 MIN LENGTH 6 CDV NOT SEND CD ...

Page 37: ...t fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology NOTES P023 RESET ABORT 1 The scanner will beep three times as indication that a setting is not yet complete or unexpected barcode is scanned during multi step configuration 2 If you make a mista...

Page 38: ...ART STOP CLSI FORMAT Example of ST Start SP Stop 123456 Not Transmit ST SP A123456B ST SP ABCD ABCD a123456b ST SP abcd abcd A123456N ST SP ABCD TN E a123456n ST SP abcd tn e CLSI Enable library space insertion If you enable the CLSI format this option inserts spaces in position 2 7 13 of the data string for use in library systems I 001 I 002 I 005 I 006 I 007 I 008 I 009 I 030 I 029 I 031 I 032 I...

Page 39: ...t fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology NOTES P023 RESET ABORT 1 The scanner will beep three times as indication that a setting is not yet complete or unexpected barcode is scanned during multi step configuration 2 If you make a mista...

Page 40: ...an Blood Commission This bar code is a variant of the CODABAR Code developed for the use in the blood bank This Code consists of two bar codes which are decoded in one read cycle The code is concatenated when the stop character of the first bar code and the start character of the second bar code is a D these two D are not transmitted The CX Code consists of two bar codes which are decoded in one r...

Page 41: ...he data can be any alphanumerics of FULL ASCII Table GROUP 40 46 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a step etc Scan RESET to start again If CODABAR ADJACENT is enabled the scanner will only read two adjacent Codabar bar codes a single bar code will not be read Step 1 Scan SET INSERT DATA Step 2 Scan any combination of...

Page 42: ...ART STOP Not SEND G001 FULL ASCII CODE 39 ENABLE K015 TAILING NOT SEND K014 TAILING SEND K013 LEADING NOT SEND K010 ENABLE K011 DISABLE K012 LEADING SEND GROUP 30 SYMBOLOGIES STANDARD FULL ASCII CODE 39 CODE 32 STANDARD CODE 39 FULL ASCII 39 CODE 32 NOTE The default for Code 39 is Standard Code 39 If Full ASCII Code 39 is enabled Standard Code 39 will be automatically disabled ...

Page 43: ...t fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology NOTES P023 RESET ABORT 1 The scanner will beep three times as indication that a setting is not yet complete or unexpected barcode is scanned during multi step configuration 2 If you make a mista...

Page 44: ... H047 ADD A SPACE ON H048 ADD A SPACE OFF H055 ADDENDA REQUIRED OFF H056 ADDENDA REQUIRED ON GROUP 31 SYMBOLOGIES FORMATTING UPC E UPC E ADD ON SUPPLEMENT If ADDENDA REQUIRED is set to ON the scanner will only read an UPC E bar code that has an addenda At the same time please also scan 5 ON or 2 ON so the scanner will output a 5 digit or 2 digit addendum NOTE ...

Page 45: ...ost UPC bar codes lead with 0 number systems for these bar codes use UPC E 0 selection For the bar codes that lead with the 1 number use UPC E 1 selection 1 If UPC E EXPAND TO UPC A FORMAT is enabled the output of UPC A will be 12 digits 2 The default output of UPC A is 12 digits if UPC A EXPAND TO EAN13 is enabled a zero will be added to in front of the bar code ...

Page 46: ...6 ADD A SPACE OFF H067 DISABLE H068 ENABLE ADDENDA REQUIRED ON H060 ADDENDA REQUIRED OFF H059 GROUP 33 SYMBOLOGIES FORMATTING UPC A UPC A UPC A EXPAND TO EAN 13 ADD ON SUPPLEMENT If ADDENDA REQUIRED is set to ON the scanner will only read an UPC E bar code that has an addenda At the same time please also scan 5 ON or 2 ON so the scanner will output a 5 digit or 2 digit addendum NOTE ...

Page 47: ...ON H043 H044 ADD A SPACE OFF ENABLE H019 ADDENDA REQUIRED ON H062 ADDENDA REQUIRED OFF H061 If ADDENDA REQUIRED is set to ON the scanner will only read an UPC E bar code that has an addenda At the same time please also scan 5 ON or 2 ON so the scanner will output a 5 digit or 2 digit addendum NOTE GROUP 34 SYMBOLOGIES FORMATTING EAN 8 EAN 8 ADD ON SUPPLEMENT ...

Page 48: ...EMENT ISBN ISSN Both ISSN and ISBN are the extension codes of EAN 13 If scanner is required to read either ISSN or ISBN EAN 13 must be enabled Otherwise the scanner will not be able to read ISSN or ISBN NOTE NOTES 1 If ADDENDA REQUIRED is set to ON the scanner will only read an EAN 13 bar code that has an addenda 2 Either ISSN or ISBN will be considered as an extension of EAN 13 If ISSN or ISBN ne...

Page 49: ... J012 MIN LENGTH 5 J013 MAX LENGTH 48 GROUP 36 SYMBOLOGIES EAN UCC 128 CODE 128 EAN UCC 128 CODE 128 NOTES DEFINE EAN 128 String format Setting Procedure The first FNC1 character is translated to c1 and the second FNC1 character is translated to an ASCII GS character scan from Group 40 46 1 Scan DEFINE EAN128 2 Scan ASCII Code Group 40 46 3 Scan DEFINE EAN128 ...

Page 50: ...ND N039 GS1 DataBar STACKED DISABLE N010 GS1 DataBar LIMITED ENABLE N012 GS1DataBarLIMITEDCHECKDIGITSEND N024 GS1 DataBar LIMITED PREFIX SEND P019 GS1 DataBar LIMITED SET ID N011 GS1 DataBar LIMITED DISABLE N013 GS1DataBarLIMITEDCHECKDIGITNOTSEND N025 GS1 DataBar LIMITED PREFIX NOT SEND N026 GS1 DataBar EXPANDED ENABLE N028 GS1DataBarEXPANDEDSTACKEDENABLE N030 GS1 DataBar EXPANDED MIN LENGTH P020 ...

Page 51: ... F H J D L B U N I K M G E C A O GROUP 38 FULL ASCII TABLE CODE 39 CONTROL CODES NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI ...

Page 52: ... T V X Z P R D B Q W Y A S U C E GROUP 39 FULL ASCII TABLE CODE 39 CONTROL CODES DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US SP ...

Page 53: ... F H A C V J Q S L N 0 GROUP 40 FULL ASCII TABLE CODE 39 SYMBOLS ...

Page 54: ... B F J G Z I G I H L P R T W K M GROUP 41 DEL FULL ASCII TABLE CODE 39 SYMBOLS ...

Page 55: ...I K L G M H J A C E B F D A B C D E F G H I J K L M GROUP 42 FULL ASCII TABLE CODE 39 UPPER CASE ALPHABETS ...

Page 56: ...X Z V Y W N T P R O S Q U GROUP 43 N O P Q R S T U V W X Y Z FULL ASCII TABLE CODE 39 UPPER CASE ALPHABETS ...

Page 57: ... F H J L G I K M E B A C D GROUP 44 a b c d e f g h i j k l m FULL ASCII TABLE CODE 39 LOWER CASE ALPHABETS ...

Page 58: ... U W Y V X Z T N P R O Q S FULL ASCII TABLE CODE 39 LOWER CASE ALPHABETS GROUP 45 n o p q r s t u v w x y z ...

Page 59: ...FULL ASCII TABLE CODE 39 NUMBERS GROUP 46 0 1 2 3 4 5 6 7 8 9 ...

Page 60: ...FULL ASCII TABLE CODE 39 FUNCTION KEYS GROUP 47 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Home End Enter Numeric Key App TA TB TC TD TE TF TG TH TI TJ TK TL TM TN T D T O ...

Page 61: ... TU TW TS TQ TY TO TZ TV TT TR TX TP T K FULL ASCII TABLE CODE 39 NAVIGATION KEYS GROUP 48 Cursor Right Cursor Left Cursor Up Cursor Down Page Up Page Down Tab Back Tab Esc Enter BS Ins Del ...

Page 62: ...Right make T E Alt Right make T M Win Right make T K Win Left make T I Shift Right make FULL ASCII TABLE CODE 39 MODIFIER KEYS GROUP 49 For UK Keyboard Special Character Note 1 When Alt Left Make is programmed please scan Alt Left Break to resume barcode setting 2 When Shift Left Make is programmed please scan Shift Left Break to resume barcode setting 3 When Ctrl Left Make is programmed please sc...

Page 63: ...te Format DD MM YYYY Time Format HH MM SS 20 22 Enable Disable Symbologies e l b a s i D 2 3 e d o C China Postal Code Disable UK Plessey Code Disable Industrial 2 of 5 Disable Matrix 2 of 5 Disable Interleaved 2 of 5 Enable e l b a n E 8 2 1 e d o C e l b a n E r a b a d o C e l b a s i D n e p e l e T e l b a n E A C P U e l b a n E E C P U e l b a n E 8 N A E e l b a n E 3 1 N A E e l b a s i D...

Page 64: ...able Check Digit Verification Disable CDV Min Length 6 Max Length 48 27 Codabar Enable Disable Enable Check Digit Verification Disable CDV Min Length 6 Max Length 48 d n e S p o t S t r a t S Start Stop Type ST SP ABCD ABCD CLSI Format CLSI Format OFF 28 ABC Codabar F F O F F O N O Insert Data Insert Data OFF CX Codabar F F O F F O N O Insert Data Insert Data OFF 29 Codabar Coupling F F O F F O N ...

Page 65: ...ble Check Digit Verification Send CD d n e S t i g i D d a e L F F O 5 F F O 2 Add a Space OFF Addenda Required OFF F F O N B S I F F O N S S I F F O N M S I 36 EAN UCC 128 Enable Disable Enable Func 1 Char Not Send Code 128 Enable Disable Enable Min Length 5 Max Length 48 37 GS1 Databar Enable Disable Disable Check Digit Verification Not Send CD d n e S t o N x i f e r P GS1 Databar Stacked Omnid...

Page 66: ...APPENDIX 2 BAR CODE TEST CHART MEDIUM DENSITY NW 7 CODABAR CODE 39 Interleaved 2of5 UPC EAN DENSITY MEDIUM DENSITY NARROW mm mil WIDE mm mil CHAR GAP mm mil N W RATIO 0 25 10 0 625 25 0 25 10 1 2 5 ...

Page 67: ...APPENDIX 2 BAR CODE TEST CHART DENSITY LOW DENSITY NARROW mm mil WIDE mm mil CHAR GAP mm mil N W RATIO 0 33 13 0 825 32 5 0 33 13 1 2 5 LOW DENSITY ...

Reviews: