6.1. BLAST CHILLING AND FREEZING FUNCTIONALITY
Blast Chilling and Freezing cycle have two main
working option: controlled by temperature or by
time:
•
If operator chooses
TEMPERATURE
cycle
option, temperature will be detected by needle
probe “n2P” and cycle will end once needle probe
reaches the pre-setting temperature accord-
ing to value of par3°C for chilling and
-18°C for freezing. After cycle ends the device
will switch automatically to “storage mode” that
will keep the stored food at a pre-setting tem-
perature: ch2°C; freezing -20°C until the
storage mode status will be ending by pressing
“START/STOP”
key.
During the temperature cycle the display will
show always the value of needle probe temper-
ature “n2P”. Once storage cycle starts the dis-
play will show the value of chamber temperature
“rNP”.
NOTE
: End user can modify the pre-setting end-
ing needle probe temperature: (AFTER CYCLE SE-
LECTION but BEFORE PRESS START/STOP
key).Press and release the UP
or DOWN
keys before start the cycle, the display will show
the set point of temperature meantime the
icon start flashing. Then press
or
keys to
modify the set point and confirm the new param-
eter pushing
key. The modify value will be
stored. If end user don’t confirm the new value by
key, the device will back to pre-setting tem-
perature value (-18°C) after 15s.
•
If operator chooses
TIME
cycle option, tem-
perature will be detected by chamber probe
“rNP” and thermostat display will show pre-set-
ting time cycle of 120 Min. for chilling and 240
Min. for freezing. Once chamber temperature
reaches a pre-set value of +3°C for chilling and
-18°C for freezing the compressor will stop. Cy-
cle will end once the pre-setting duration cycle
time will reach 0 min.
After ending cycle the device will enter in a “stor-
age mode” that will keep the stored food at pre-
setting temperature according to the value of pa-
rameter: ch2°C; freezing -20°C until the
storage mode status will be ending by pressing
“START/STOP”
key. During the time cycle the
display will show time left to finish the cycle. Once
storage cycle starts the display will show the val-
ue of chamber temperature “rNP”.
NOTE
: End user can modify the pre-setting time
as follow: (AFTER CYCLE SELCTION BUT BEFORE
PRESS START/STOP
key). Press and release
the UP
or DOWN
keys before start the cy-
cle, the display will show the presetting time cy-
cle in decimal unit (1 = 1min.) meantime the
+
+
icons start flashing. Then press
or
keys to modify the time and confirm the new
time value pushing
key. The modify value will
be stored. If end user don’t confirm the new value
by
key, the device will back to pre-setting time
value (120 min.) after 15s.
6.2. POSSIBLE OPERATION CYCLES:
• SOFT CHILLING CYCLE
• HARD CHILLING CYCLE
• SOFT FREEZING CYCLE
• HARD FREEZING CYCLE
• ICE CREAM CYCLE
• FROST BUST -40°C CYCLE