SOFT FREEZING CYCLE
Operate as follows to start the Temperature soft
freezing cycle:
The temperature-controlled Soft Freezing cycle is
split in the following 3 phases:
• Blast Freezing Soft phase
• Blast Freezing
• Storage
SOFT cycle is used when the end user wants a
smooth freezing process (during the softh phase
the chamber temperature will never go down to
a negative temperature). Once the needle probe
reaches temperature of +3°C (“iS1” parameter val-
ue) the SOFT BLAST FREEZING PHASE stops and a
Blast freezing cycle starts.
• Press twice and release Blast Freezing
keys,
the Freeze
led icons will start flashing.
• Press one time HARD/SOFT key
, led icon
will be OFF.
• To select TIME cycle, press twice Blast Freezing
key, the freeze
led icon will be flash-
ing, press one time
+
keys for 3s, the
time led icon
will be flashing and icon
will switch OFF.
• Press and release START/STOP
key to start
freezing soft cycle: the Compressor LED icon
+
plus
and needle probe
led icon
will switch ON permanently. (Time cycle will be
ON
instead).
• Once the needle probe temperature reaches the
pre-setting point or time cycle is ending, a visual
and acustic alarm will notify the ending cycle, the
unit will start a storage cycle and led icon will
flashing.
NOTE
: During the storage cycle the display will
show chamber temperature “rNP”.
HARD FREEZING CYCLE
Operate as follows to start the Temperature hard
freezing cycle:
The temperature-controlled hard Freezing cycle is
split in the following 3 phases:
• Blast Chilling Hard phase
• Blast Freezing
• Storage
HARD cycle is used when the end user wants a fast
blast freezing process (Chamber temperature will
reach a temperature of -20°C (“rS1” parameter
value). Once the needle probe reaches a temper-
ature of +3°C (“iS2” parameter value) the HARD
BLAST CHILLING PHASE stops and a BLAST FRE-
ZEEZING phase start.
• Press twice and release Blast Freezing
keys, the Freeze
led icons will start flash-
ing and
led icon will be ON.
• To select TIME cycle, press twice Blast Freezing
key, the freeze
led icon will be flash-
ing, hold
keys for 3s, the time led icon
will be flashing.
• Press and release START/STOP
key to start
freezing hard cycle: the Compressor LED icon
+
plus
,
and needle probe
led icon will switch ON permanently. (Time
cycle will be ON
instead).
• Once the needle probe temperature reaches the
pre-setting point or time cycle is ending, a visual
and acustic alarm will notify the ending cycle, the
unit will start a storage cycle and led icon will
flashing.
NOTE
: During the storage cycle the display will
show chamber temperature “rNP”.
12