• Must not be cleaned by a water jet.
• Always wipe dry after cleaning with soft cloth.
• Do not allow water used in cleaning to run
through the drain hole into the evaporation pan.
• Take care when cleaning the rear of the appliance.
• An agent or technician must carry out repairs if
required.
• If the appliance is to be left inactive for long
periods, unplug the appliance after having turned
the switch to OFF position, empty the refrigerat-
ing compartment and clean thoroughly.
• Blast chiller maintenance must include at least
one daily cleaning of the temperature needle
probe.
• It is recommended to deeply rinse the needle
probe with clean water and a sanitizing solution
Special maintenance
The instructions given in the following paragraph
can be followed from qualified technicians
• Periodically clean the condenser using suitable
tools (vacuum cleaner or soft brushes) can extend
the life of the appliance.
• Check that the electrical connections are not
loose.
• Check that the thermostat and the sensor are in
proper working order.
9. OPTIONAL ACCESORIES
Four pieces of Castor
• Positioning: Two castors with break to be fixed at
the bottom front and two castors with no break to
be fixed at the bottom rear.
• Procedure: Follow the 12 steps below to change
the footings to castors.
NOTE
: If you intend to purchase optional accesso-
ries, please ask our sales staff for advice
CAUTION
:
• Unplug the appliance from main socket before
change.
• Securing the fork lift before change.
• Securing all drawers, shelves, lids and doors be-
fore change.
• Empty the cabinet before change.
• Lock the brake on the caster after change