If switch ON a “ICE CREAM” cycle is in progress, if both of the icons flashing a cycle has been
selected (Temperature is detected by Chamber probe “rNP”).
If switch ON an ALARM is in progress, check “trouble shooting” instruction (chapter 10)
NOTE
: Alarm icon/Alarm displayed labels:
• When the are one or more than one alarm events,
it or them must be visible on the display and
buzzer will be ON (Acoustic alarm)
• Whatever button will be pushed, the buzzer will
be switched OFF, but the alarm icon and label
will be still visible.
• The alarm icon and labels will be visible until
the user will check and acknowledge the alarm
situation. Press button
for 5s to manual re-
set.
I. To switching the device ON/Stand-by mode
• Hold the START/STOP key
for 3s, the icon
will be ON.
• Hold the START/STOP key
for 3s, the icon
will be OFF and the display will show the
chamber temperature “rNP”.
II. To select Temperature cycle
• Press and release the chilling/freezing cycle key
, needle probe icon
+
will be
flashing and selected.
NOTE
: Temperature cycle has been chose as a
default setting for both Chilling/Freezing cycle.
III. To select Time cycle
• Press and release the chilling/freezing cycle key
, press and hold
key for 3s.
• Time cycle icon
+
will be flashing and
selected.
IV. To start or stop the cycle
• Press and release the START/STOP key
, the
running cycle will be ending and on the display
will appear the room temperature “rNP”.
V. How to display “Chamber temperature” probe
value.
• Hold the frost buster key
for 3s, the display
will show the label “rNP”.
• Press and release
key, the display will show
chamber temperature.
• To exit procedure: Press and release the combi-
nation combo key
+
or don’t operate for
3s, the display will show “n2P” value or timing
cycle left.
VI. How to display “Needle probe temperature”
value
.
• Hold the frost buster key
for 3s, the display
will show the label “rNP”.
• Press and release twice
key, the display will
show “n2P”, press
key again for see the nee-
dle probe temperature value.
• To exit procedure: Press and release the combi-
nation combo key
+
or don’t operate for
3s, the display will show “rNP” value or timing
cycle left.
VII. How to activate a Defrosting cycle.
• No any cycle should be selected or in progress
• Hold the UP ARROW key
for 3s, the defrost
and fans icons
+
will be ON and display
will show “dEf” label.
• To exit procedure: if end user prefer interrupt the
defrost cycle, Press and hold START/STOP key
for 3s, item will be OFF and switch to stand-
by mode.
• When device will be ending defrost cycle, the dis-
play will show room temperature “rNP” value.
NOTE
: not mandatory, but is recommended keep
the door open during defrost cycle.