Summary of Contents for CORE PLUS

Page 1: ...1 MANUAL ...

Page 2: ...fter attachment 10 6 Attachment location 11 7 Step by step instructions for attachment 12 8 Schematic view of attachment 15 9 Power adapter 16 10 Pictograms stickers 17 Use 18 1 Opening the ARKY Core Plus 18 2 Closing the ARKY Core Plus 19 3 Step by step instructions for emergencies 20 4 After using the AED 21 5 Maintenance and cleaning 21 Specifications 22 Table of contents ...

Page 3: ...wall taking into account the minimum clearance space and applicable fire safety regulations Safety Ensure that the power is off when carrying out maintenance and or when connecting the ARKY Core Plus Leave a clearance of at least 30 cm around the ARKY Core Plus to ensure proper ventilation Take into account the minimum clearance space and applicable fire safety regulations Always keep the area und...

Page 4: ...ce and applicable fire safety regulations Front Back 1 3 6 2 2 Identification plate Always state the type designation and serial number when contacting customer service or your supplier Identification plate Installation Please read these instructions in full before installing and using the ARKY Core Plus I N S TA L L AT I O N 1 Wall section 2 Cap 3 Base 4 Two heating elements 5 Pinlock 6 PCB compa...

Page 5: ...then be entered again starting from the first digit OK was pressed after entering an incorrect code There will be two beeps The code can then be entered again starting from the first digit The pinlock was pressed in or the code was not entered in full without pressing OK After 20 seconds the entry is automatically deleted The code can then be entered again starting from the first digit TIP Change ...

Page 6: ...igure 6 Attachment location Enclosed fixing materials 2 x washer M5 zinc plated 4 x plug 8 x 40 mm 4 x Torx screw 5 x 50 mm 1 x Torx driver 1 x drilling template PLEASE NOTE Use fixing materials that are suitable for the type of surface to which the ARKY Core Plus is being fitted The minimum bearing capacity required is 20 kg Screw diameter max 8 mm Collar diameter max 12 mm 630 mm 430 mm 100 mm 1...

Page 7: ...in full sunlight It should ideally be situated in a shaded location on a flat wall b Take into account the minimum clearance space and applicable fire safety regulations 7 Fit the mounting holes with plugs except for the cable inlet 8 Only fit the top two mounting holes with a Torx screw and washer Tighten the screw and washer with the Torx driver and ensure a minimum distance of 3 mm between the ...

Page 8: ...fault code 1 5 1 5 OK carry out the steps outlined in section 3 if a different code is required 15 With the cabinet open fit the lower mounting holes with a bolt screw and a sheet metal washer if necessary 16 Tighten all bolts including the top two with the enclosed open end spanner or use a ratchet spanner 17 The cabinet has been installed and is ready for use PLEASE NOTE The minimum voltage requ...

Page 9: ...hen carrying out maintenance and or when connecting the ARKY Core Plus PLEASE NOTE When setting a code other than the default code it can be helpful to temporarily keep the power cable on the inside as long as possible and not to fix it with cable clips for example so as to ensure freedom of movement Always place the power adapter inside 10 Pictograms stickers Press code Press ok 1 2 A B C D E A B...

Page 10: ... then confirm with OK The base moves down automatically Centre the AED on the aluminium plate against the rear wall as soon as the base moves no farther downwards Place a hand on either side of the base and push upwards until the base locks firmly into the wall section Use 1 2 3 Enter the code The base moves down Place AED in the centre ...

Page 11: ...ing the ARKY Core Plus Clean the surfaces of the ARKY Core Plus with a soft damp cloth Do not use chemical based products or cleaning agents as these may damage the cabinet s plastic enclosure Dry the ARKY Core Plus with a soft dry and clean cloth Do not rub the cabinet with a hard object This may permanently damage the cabinet Do not use a high pressure cleaner to clean the ARKY Core Plus 1 Call ...

Page 12: ... C and 50 C Heating ventilation The ARKY Core Plus is equipped with five fans and two heating elements of 24 V 45 W Heating Switches on at 7 C Switches off at 10 C Ventilation Switches on at 40 C Switches off at 35 C Alarm If the correct code is entered on the pinlock when the ARKY Core Plus is powered by a suitable power supply the cabinet will open and an acoustic alarm will sound The alarm will...

Page 13: ...ARKY Verlengde Bremenweg 12 9723 JV Groningen The Netherlands 31 0 50 31 16 085 sales arkycase com www arkycase com ...