0b111
512 Architectural Timer ticks are required before retention entry.
This field is present only if the Advanced SIMD and floating-point support is implemented.
Otherwise, it is
RES0
.
CPURETCTL, [2:0]
CPU retention control. The possible values are:
0b000
Disable the retention circuit. This is the reset value.
0b001
2 Architectural Timer ticks are required before retention entry.
0b010
8 Architectural Timer ticks are required before retention entry.
0b011
32 Architectural Timer ticks are required before retention entry.
0b100
64 Architectural Timer ticks are required before retention entry.
0b101
128 Architectural Timer ticks are required before retention entry.
0b110
256 Architectural Timer ticks are required before retention entry.
0b111
512 Architectural Timer ticks are required before retention entry.
To access the CPUECTLR:
MRRC p15, 1, <Rt>, <Rt2>, c15; Read CPU Extended Control Register
MCRR p15, 1, <Rt>, <Rt2>, c15; Write CPU Extended Control Register
Register access is encoded as follows:
Table B1-37 CPUECTLR access encoding
coproc opc1 CRm
1111
0001 1111
B1 AArch32 system registers
B1.43 CPU Extended Control Register
100236_0100_00_en
Copyright © 2015–2017, 2019 Arm Limited or its affiliates. All rights
reserved.
B1-213