A4.9
Powering up the processor without system driven L2 flush
When powering down the processor, the PDMERCURY, PDL2, and PDCPU power domains are shut
down and all state is lost.
To power up the processor, apply the following sequence:
Procedure
1. For each core in the cluster, assert
nCPUPORESET
LOW.
2. Assert
nL2RESET
LOW and hold
L2RSTDISABLE
LOW.
3. Apply power to the PDMERCURY and PDL2 domains while keeping the signals described in steps
LOW.
4. Release the cluster output clamps.
5. Continue a normal cold reset sequence.
A4 Power Management
A4.9 Powering up the processor without system driven L2 flush
100236_0100_00_en
Copyright © 2015–2017, 2019 Arm Limited or its affiliates. All rights
reserved.
A4-68