System Control
ARM DDI 0337G
Copyright © 2005-2008 ARM Limited. All rights reserved.
3-9
Unrestricted Access
Non-Confidential
Instrumentation Trace Macrocell registers
Table 3-5 gives a summary of the
Instrumentation Trace Macrocell
(ITM) registers. For
a detailed description of the ITM registers, see Chapter 11
System Debug
Table 3-5 ITM register summary
Name Type
Address
Reset
value
Stimulus Ports 0-31
Read/write
0xE0000000
-
0xE000007C
-
Trace Enable
Read/write
0xE0000E00
0x00000000
Trace Privilege
Read/write
0xE0000E40
0x00000000
Trace Control Register
Read/write
0xE0000E80
0x00000000
Integration Write
Write-only
0xE0000EF8
0x00000000
Integration Read
Read-only
0xE0000EFC
0x00000000
Integration Mode Control
Read/write
0xE0000F00
0x00000000
Lock Access Register
Write-only
0xE0000FB0
0x00000000
Lock Status Register
Read-only
0xE0000FB4
0x00000003
PID4
Read-only
0xE0000FD0
0x00000004
PID5
Read-only
0xE0000FD4
0x00000000
PID6
Read-only
0xE0000FD8
0x00000000
PID7
Read-only
0xE0000FDC
0x00000000
PID0
Read-only
0xE0000FE0
0x00000001
PID1
Read-only
0xE0000FE4
0x000000B0
PID2
Read-only
0xE0000FE8
0x0000002B
PID3
Read-only
0xE0000FEC
0x00000000
CID0
Read-only
0xE0000FF0
0x0000000D
CID1
Read-only
0xE0000FF4
0x000000E0
CID2
Read-only
0xE0000FF8
0x00000005
CID3
Read-only
0xE0000FFC
0x000000B1