Target
Device
nTRST
nRESET
nRST
Manual
Reset
10K
100R
SYSTEM RESET
Open-drain
reset device
e.g. STM1001
10K
100nF
TAP RESET
Other
Devices
Debug
Connector
nTRST
nSRST
VDD
VDD
VDD
Figure 1-8 Example reset circuit
The push-button, 100R resistor, and 100nF capacitor shown here are an example of how a manual reset
button can be interfaced with the
nSRST
signal. This is optional and would typically be used on
development boards.
The reset device that is shown here would keep the target device, and any other system devices, in their
reset state until the power rail has reached a minimum valid voltage. If the target device has a separate
Power On Reset (POR) input, any voltage monitoring devices would typically connect to that instead. If
the target device is equipped with internal voltage monitoring circuitry, external monitoring devices can
be omitted.
1 Debug and trace interface
1.3 Reset signals
101714_0100_02_en
Copyright © 2019 Arm Limited or its affiliates. All rights reserved.
1-20
Non-Confidential