13
may be struck by electric shocks.
Capacitance measurement
1)
Turn the knob to ”
” shift.
2)
Insert the red probe in “
” socket
,
insert the black
probe in “COM” socket
。
3)
Contact the probe to the measured circuit or Capacitance,
measure the resistance.
4)
Read the measurement result on the screen.
5)
WARNING
When measuring Capacitance on the line, disconnect the
power supply and discharge all the high-voltage
capacitors. Otherwise, the instrument may be damaged and
may be struck by electric shocks.
Continuity measurement
1)
Turn the knob to
shift and Switch to Continuity
measurement function according to "FUNC." key.
2)
Insert the red probe in “
” socket
,
insert the black
probe in “COM” socket
。
3)
Contact the probe to the measured circuit or resistance,
4)
If the resistance or circuit of the measured resistance is less
than 30Ω, the buzzer will on and the green indicator lights
up at the same time; when the resistance is about between
30Ω to 60Ω, the red indicator lights up; the screen displays