Clamp
Meter
2
Power Source:
1.5V size AAA battery X 2
Typical battery Life: (without buzzer, backlight)
40 hours at ACmA and ACA and ACV function;
60 hours at DCV and Ohm function. (alkaline battery)
Auto Power Off:
If there is no key or dial operation for 30 minutes, the meter will power
itself off to save battery life. This function can be disabled by pressing
and holding the “
HOLD
” button and powering on the unit.
Over Load:
When the applied signal is larger than the maximum for the range in
use the display will show
.
Maximum jaw opening:
23 mm
Dimensions:
206 x 76 x 33.5 mm
Weight:
262g (with battery)
Accessories:
Carrying case, Batteries, Test Lead & Instruction Manual.
3. ELECTRICAL SPECIFICATION
The accuracy specification is defined as ± ( percent of r digit )
≦
At 23±5°C, 80 %RH.
3-1 ACmA (True RMS)
Range Resolution
Accuracy
50~60Hz 50~500Hz
6.000mA
0.001mA
1.0% + 8dgts
2.0% + 8dgts
60.00mA 0.01mA
1.0% + 5dgts
2.0% + 5dgts
600.0mA 0.1mA
Zero correction: Fractions smaller than approximately 0.006 mA are
calibrated to zero.
Low Pass Filter
Range Resolution
Accuracy
6.000mA
0.001mA
2.0% + 8dgts
60.00mA 0.01mA
2.0% + 5dgts
600.0mA 0.1mA
Summary of Contents for Pro95
Page 1: ...Model Pro95 TRUE RMS MILLIAMP CLAMP METER...
Page 2: ......
Page 15: ......
Page 16: ...GCBARM265 R0200 Armada Technologies www armadatech com...