507746-01
Issue 1821
Page 2 of 39
OPTIONAL
ELECTRIC HEAT
(FIELD-INSTALLED)
AIR
FLOW
LIQUID
LINE
SUCTION
LINE
SUPPLY AIR
OPENING
RETURN AIR
FILTER
LOW VOLTAGE
INLETS (TOP AND
RIGHT SIDE)
RETURN AIR
TOP VIEW
FRONT VIEW
SIDE VIEW
BLOWER
PIPING PLATE DETAIL
(FOR UP-FLOW AND DOWN-FLOW POSITIONS)
A
C
B
11
‐
1/16 (281)
D
F
E
LIQUID LINE
SUCTION LINE
CONDENSATE DRAINS
(2) (HORIZONTAL)
COIL
3/4 (19)
3/4 (19)
5/8 (16)
)
5
2
(
1
)
6
1
(
8
/
5
5/8 (16)
1
‐
3/4 (44)
2
(51)
1
‐
1/8 (29)
4
‐
3/8 (111)
2
‐
3/4
(70)
5
‐
3/8
(137)
3
‐
1/2 (89)
OPTIONAL
ELECTRIC HEAT
(FIELD-INSTALLED)
AIR FLOW
LIQUID
LINE
SUCTION
LINE
Return
Air Opening
SUPPLY
AIR
FILTER
SUPPLY AIR
TOP VIEW
FRONT VIEW
SIDE VIEW
BLOWER
A
B
C
11
‐
1/16 (281)
F
D
E
COIL
5/8 (16)
5/8 (16)
5/8 (16)
5/8 (16)
5/8 (16)
LOW VOLTAGE
(RIGHT SIDE)
LINE VOLTAGE
(LEFT SIDE)
DOWN-FLOW POSITION
1 (25)
UP-FLOW POSITION
CONDENSATE DRAINS
(2) (UP-FLOW AND
DOWN-FLOW)
FILTER ACCESS
FILTER ACCESS
H
G
H
G
LINE VOLTAGE
INLETS (TOP
AND LEFT SIDE)
5/8 (16)
5/8 (16)
Unit Dimensions
Upflow and Downflow Unit Dimensions - Inches (mm)
Common Dimensions
Dimension
24
30/36
42/48
60
in.
mm
in.
mm
in.
mm
in.
mm
A
49-1/4
1251
51
1295
58-1/2
1486
62-1/2
1588
B
21-1/4
540
21-1/4
540
21-1/4
540
21-1/4
540
C
20-5/8
524
22-5/8
575
24-5/8
625
24-5/8
625
D
19-3/4
502
19-3/4
502
19-3/4
502
19-3/4
502
E
19
483
21
533
23
584
23
584
F
20
508
20
508
20
508
20
508
G
24-5/8
625
26-3/8
670
27-7/8
708
27-7/8
708
H
24-5/8
625
24-5/8
625
30-5/8
778
34-5/8
879