12
ii)
Allow the solution to work until the boiling action ceases.
iii) Clean the water level electrodes, using an emery cloth. See Page 15 for
complete instructions.
iv) Check water level canister for debris.
v)
Replace the electrodes.
vi) Ensure drain lines are free of leaks and secure.
vii) Fill the tank with water and drain. (Perform this step several times.)
b)
Install the new Ionic Beds.
5) Restoring the Unit to Operation
c)
Put “STEAM GENERATION” switch on the “ON” position.
d)
Turn power on at breaker, the LED’s will illuminate for 5 seconds, then go off
except for the “POWER ON” LED.
e)
Unit should begin to fill. Fill time is approximately 23 minutes before “STEAM
GENERATION LED” will come on.
f)
If this does not take place, reset the unit by holding the “RESET” button “ON”
(to the left) for 20 seconds until the front panel LED’s illuminate and than all
go off (except for the “POWER ON” LED).
B. Modifying the Bed Life Setting
1)
Complete the steps for servicing the unit as outlined above.
2)
The unit must run for at least one hour.
3)
Power the unit down.
4)
Set the dip switches to the desired EOL settings. See Page 22 for table of dip switch
settings.
5)
Power the unit up. The new Bed Life Settings will be set.
Note: If the dip switches are reset prior to the completion of step two, the unit could
lock up. The power on LED will be lit, but the unit will not respond to any input. If this is
the case, the following steps must be taken to restore the unit to proper operation.
a)
Power the unit down.
b)
Reset the dip switches to the previous settings as recorded (Factory Defaults
are HC-4100 = 1000 hours, HC-4300 & HC-4500 = 500 hours).
c)
Power the unit up at breaker.
d)
Press and hold the “RESET” button to reset the EOL time. This must be held
for at least 20 seconds.