background image

ACM-IP2 ANALOGUE SUBSYSTEMS MODULE

  

User Manual 

page 14/28 

 

armtel.com 

© Armtel 

 

 info@armtel.com

 

ENG 

2 INTENDED USE 

The product is designed for continuous 24-hour a day operations. After 

commissioning, the product does not require operator intervention, unless: 

 

maintenance; 

 

product configuration changes. 

Maintenance personnel must be strictly guided by this document in compliance with 

safety regulations. 

The product along with the operational documentation is delivered to the customer in 

packaged form. 

2.1 Operating limits 

2.1.1 ACM-IP2 shall be used under exposure factors and ambient parameters 

which do not exceed permissible values given in Table 2. When using the product, 
safety precautions laid out in “Occupational safety rules when operating electrical 
installations” should be complied with when working with electrical receivers with 
voltage of up to 1000 V. 

2.1.2 In case of lack of power supply PoE plus, in addition to connecting  

the communication cable, it is necessary to supply an external 48 V supply from a DC power 

source with a power of at least 30 W to contacts 2, 3 of the socket X21 of the ACM-IP2. The 

connection should be carried out with a 2-core cable with a cross section of at least 0.35mm

2

2.1.3 When installing ACM-IP2 (version RMLT.465275.006-01) together with the  

ADSL-IP2 Adapter in fully enclosed metal telecommunication cabinets, stable operation of 

the product via wireless Wi-Fi communication is not guaranteed. 

2.1.4 A restart may delay the initialization of the ACM-IP2. This feature is characteristic 

in case of power supply by PoE plus line, as well as using the ADSL communication line (in 
case of restarting the IP DSLAM). 

2.1.5 The requirements for operating conditions and the choice of the place of 

installation given in this document take into account the most typical factors that 

affect the operation of ACM-IP2. 

Factors that cannot be predicted, estimated or verified, and which the manufacturer 

was unable to factor in during development may exist or arise during operation at the 

operating facility.  

In the event of such factors, find another operating site where said factors do not exist 

or do not affect operation of the product. 

Summary of Contents for ACM-IP2

Page 1: ...ACM IP2 Analogue subsystems module RMLT 465275 006UM User Manual Document version 12 26 30 11 190 2020 ENG...

Page 2: ...armtel com Armtel info armtel com...

Page 3: ...ides the ability to listen to recorded or broadcasted audio messages to subscriber devices by the built in amplifier Short name of product ACM IP2 Maintenance personnel for ACM IP2 shall be appointed...

Page 4: ...ecting the product to the power supply make sure the power and communication cables are properly insulated protect power and communication cables from damage To avoid electric shock do not operate the...

Page 5: ...P2 Adapter 11 1 6 Labeling 13 1 7 Package 13 2 INTENDED USE 14 2 1 Operating limits 14 2 2 Preparation for use 15 2 3 Installation connection and dismantling 15 2 4 Operation 17 3 MAINTENANCE 19 3 1 G...

Page 6: ...Included ACM IP2 can provide the following functions simplex communication with analogue and digital terminal units via Armtel IP and SIP protocols communication with analogue and digital terminal un...

Page 7: ...ace Fast Ethernet Switch Ethernet interface IP2 AW call station AW call station IP2 USB interface ADSL IP2 WI Fi access point Ethernet interface Fast Ethernet Switch Ethernet interface DIS IP2 AW call...

Page 8: ...o 60 Maximum current consumption at nominal power supply voltage for version RMLT 465275 006 mA for version RMLT 465275 006 01 mA 510 610 Bandwidth 3 dB level Hz from 300 to 6800 Communication interfa...

Page 9: ...ly V 3 3 5 0 Communication interface ADSL ADSL2 ADSL2 Communication protocol by ADSL line IEEE802 3 IEEE802 3u ITU G 992 1 992 5 Communication interface WI FI 2 4 Communication protocol for Wi Fi IEEE...

Page 10: ...me Quanti ty pcs Note RMLT 465275 006 ACM IP2 Analogue subsystems module 1 Product components RMLT 468158 001 ADSL IP2 Adapter 1 For version RMLT 465275 006 01 Wi Fi antenna NETIS PA105S 2 4 GHz 1 ARM...

Page 11: ...gn ACM IP2 is a printed board with electronic components inserted in casing and fixed on DIN rail 35 mm wide ACM IP2 external appearance and overall dimensions are given at Figure 2 a elements view b...

Page 12: ...ssages transmitted to terminal units 11 socket of discrete lines control lines software configurable or as input for connection for example direct call key of the terminal units or as output for load...

Page 13: ...s connected to it by the flexible cable supplied with the one The operating mode for ADSL IP2 Adapter ADSL or Wi Fi is set by software during configuration of ACM IP2 Communication with the ADSL IP2 A...

Page 14: ...g n protocol to operate at 2 4 GHz with a bandwidth of up to 20 MHz The speed of data transfer using Wi Fi technology reaches 300 Mbit s The adapter uses all directional Wi Fi antenna with a gain of 5...

Page 15: ...packed in consumer package cardboard box A label in Russian language and English language is glued onto the consumer package said label containing the following inscriptions and symbols product name a...

Page 16: ...ly an external 48 V supply from a DC power source with a power of at least 30 W to contacts 2 3 of the socket X21 of the ACM IP2 The connection should be carried out with a 2 core cable with a cross s...

Page 17: ...RJ 45 plugs which is connected to X1 socket or to X2 socket of RJ 45 in accordance with Figure 2 On the other side the cable is connected to a network unit with PoE plus injector function For version...

Page 18: ...of ACM IP2 to the service computer In this case to power ACM IP2 you should use PoE injector or supply 48 V to X21 socket from external DC power source Make records in the product passport about loca...

Page 19: ...ems and their solutions Problem Possible causes Solutions Orange LED on 1 or 2 socket is OFF No power vial plus line Check connection to socket 1 or 2 make sure that the cable and plug are OK The subs...

Page 20: ...ation cable ATTENTION NEVER DISMANTLE THE PRODUCT CONNECTED TO MAINS OR EXTERNAL POWER SUPPLY Do not use the product in rooms with high humidity more than 80 or conductive dust In order to ensure fire...

Page 21: ...jet The contaminants to be removed during air purge should not fall on other blocks air purging during ACM IP2 operation may be performed is required check reliability of connection to the terminals...

Page 22: ...urer at the request of the user The location time procedure and cost of the work shall be agreed on in advance 5 STORAGE Product storage conditions in the manufacturer s consumer package in unheated a...

Page 23: ...lashes solar UV radiation dust sand aerosols the shipping container on the shipping vehicle is fastened to avoid falling and collision Note ACM IP2 transportation is allowed as part of a cabinet rack...

Page 24: ...te input output 4 Lin4 Control line 4 discrete input output 5 Lin5 Control line 5 discrete input output 6 Lin6 Control line 6 discrete input output 7 Lin7 Control line 7 discrete input output 8 Lin8 C...

Page 25: ...ion keys the outputs of the dry contact relay from external automation and alarm systems can be connected to ACM IP2 2 An example for construction of zonal loud speaking alarm system with the help of...

Page 26: ...le 2 Table A 2 Designation od outputs of 100BaseT Ethernet RJ 45 socket Pin No Designation 1 Data transfer TX 2 Data transfer TX 3 Data receiving RX 4 PoE_VDD 5 PoE_VDD 6 Data receiving RX 7 PoE_GND 8...

Page 27: ...Adapter is illustrated in Table 3 Table A 3 Designation of outputs of RJ 12 6 6 socket Pin No Designation 1 no connected 2 no connected 3 ADSL_TIP 4 ADSL_RING 5 no connected 6 no connected External ap...

Page 28: ...Manual page 26 28 armtel com Armtel info armtel com ENG APPENDIX B REFERENCE ACM IP2 EXTERNAL APPEARANCE Figure B 1 External appearance of variant ACM IP2 RMLT 465275 001 Figure B 2 External appearanc...

Page 29: ...ACM IP2 ANALOGUE SUBSYSTEMS MODULE User Manual armtel com page 27 28 info armtel com Armtel ENG NOTES...

Page 30: ...ACM IP2 ANALOGUE SUBSYSTEMS MODULE User Manual page 28 28 armtel com Armtel info armtel com ENG...

Page 31: ...armtel com info armtel com Armtel...

Page 32: ...and physical address Russia 192012 Saint Petersburg Zaporozhskaya str 12 building 1 office 1 2 TECHNICAL SUPPORT 8 800 500 90 17 for calls from Russian Federation 7 812 633 04 02 for international ca...

Reviews: