The basin can be removed for cleaning:
- Remove the cover panel by unscrewing the flywheels (Rif. 2) and screws.
- Remove the basin and clean it.
N.B.To protect hands during this operation, wear working gloves.
After cleaning, reassemble the dry elements and plug the cabinet in. Once the internal operating
temperature has been reached, the products to be displayed can be replaced inside the cabinet.
N.B.Make sure that fans, ceiling lights, electric cables and any other electric equipment are not
wetted during cleaning.
15. Dismantling the cabinet
In accordance with the waste disposal regulations in each country and in respect of the environment
in which we live, please differentiate the parts of the cabinet so as to be able to dispose of them
separately or recycle them appropriately.
None of the parts that make up the cabinet can be disposed of together with urban solid waste, except
for the metallic components, which, in any case, are not classified as special waste in most European
countries.
Materials used in the manufacture of the cabinet:
- Iron pipe:
lower frame
- Copper, Aluminium:
refrigerating circuit, electric system, various finishings
- Galvanized steel sheet:
motor base, grids
- Plexiglass, glass:
endwalls and interior baffles
- Tempered glass:
front walls
- PVC:
plastic parts
- Foam polystyrene (R134a):
thermal insulation
This product contains HFC, a refrigerating gas with a high Global Warming Potential (GWP)
.
ARNEG equips its cabinets with refrigeration units incorporating the following types of refrigerating
gasses:
R 134a; GWP
(100)
= 1300
R 404A; GWP
(100)
= 3750
in the family of the HFCs, which are fluoridated gasses with a high global warming potential (GWP),
regulated by the Kyoto protocol (check on the rating plate or adhesive label on the compressor which
of these two gasses is used in the unit).
Therefore:
THE COMPONENTS OF THE REFRIGERATING CIRCUIT MUST NOT BE CUT OR SEPARATED,
BUT MUST BE TAKEN INTACT TO CENTRES SPECIALISED IN RECYCLING REFRIGERATING
GAS.
This unit is hermetically sealed and the refrigerating gas load is under 3 kg.
For this reason it is not subject to the requisite of an installation booklet and periodic
inspections for leakage of the refrigerating gas
(Presidential Decree no. 147 of February 15, 2006
Art. 3 and 4).
16. Useful suggestions
Please read the
Installation and Use Manual
carefully; in this way, our telephone operator will be
able to provide more precise indications as to the
Technical Assistance
required in the event of
operating problems.
Before carrying out any maintenance operation on a refrigerating cabinet, make sure that it
has been unplugged.
Should the client detect any failure in the cabinet operation, check the points below before
calling the Technical Service:
- Check that the ambient temperature and humidity values do not exceed the ones indicated.
For this reason, the air conditioning, ventilation and heating devices in the shop should always be
kept at full efficiency.
- Limit the speed of the ambient air to values lower than 0.2 m/s near the cabinet openings; in particu-
lar, it is also necessary to prevent air streams and air intakes from being directed toward the cabinet
openings.