iron remains left on damp surfaces, limestone, chlorine or ammonia based detergents not rinsed
properly, food incrustations or residues, salt-saline solutions, dry residues of evaporated liquids.
Remedy
recent stains and rust:
clean with shampoo or neutral detergents, using a sponge or a rag.
When finished, eliminate any detergent residue, rinse and thoroughly dry the surfaces.
old stains and rust:
use chemical substances on the stainless steel that contain 25% of nitric acid or similar
substances.
persistent stains and rust:
sand with a stainless steel brush, wash with detergent and dry thoroughly.
This intervention may however cause scratches to the surfaces due to the abra
-
sive cleaning method.
DO NOT
use hydrochloric acid on stainless steel surfaces
CAUTION
! Slippery floor. Falling.
Remove from the floor any items such as sponges, rags, waste of water or detergent.
Carefully clean any residue of detergent or sanitizer.
i
Carefully follow the sanitizing, rinsing and drying procedures to prevent proliferation of
harmful bacteria.
24. 7 Inspect the parts
Once you have completed sanitizing, rinsing and drying, proceed as follows:
Pitch
Action
1
check that all parts are perfectly clean and dry
2
check that they are not damaged or too worn
3
replace worn parts with new ones provided by the manufacturer
4
install the parts perfectly dry
5
restore electrical power supply.
Once the internal operating temperature has been reached, it is possible to load the products.
25. Load the refrigerant
DANGER! Coolant gas Explosion Asphyxia, alteration of cardiac pace, frostbite, anaes-
thetic effects.
BEFORE ANY OPERATION EMPTY THE ENTIRE SYSTEM!
WARNING! FIRE Burns Asphyxia
NEVER use naked flames and electrical tools next to gas
Only specialist technicians may recharge the refrigerant or work on the gas circuit according
to the European Regulation 842/2006
Check that refrigerant circuit is perfectly sealed
Only use original approved spare parts
i
To fill with refrigerant, refer to system user’s manual.
26. Dismantle the cabinet