Bergen 2
English
05060176 00 11-09-2018
39
Do not force
Replace the bulbs with new, identical models
Procedure:
Step
Action
1
disconnect the power supply from the main switch 1 (Fig.11)
2
use a screwdriver to lift the bulb base; the light bulb is of the built-in type.
3
remove the bulb
4
replace the bulb with a new identical model
5
refit the light
Upon completion, power can be re-applied to the cabinets
22. Maintenance and cleaning
DANGER! Live parts. Electrocution.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
DO NOT wet, spray water or clean directly the electrical parts of the cabinet (fans, inte
-
rior lighting, electrical cables etc.)
DO NOT touch the cabinet with wet or damp hands and feet
CAUTION
! Cold surfaces. Injuries, burning. Glass breakage.
Wait for the glass parts to reach room temperature.
DO NOT
use hot water on the cold glass surfaces.
Protect the hands with work gloves
i
The products will deteriorate due to germs and bacteria.
Compliance with Hygiene Standards and the cold chain is indispensable to guarantee the
protection of consumer health
The cleaning operations must include:
Step
Name
Description
1
Washing
roughing, removal of approximately 97% of the dirt
2
Sanitization
cdisinfection:
-
cleansing
: removal of visible dirt
-
disinfection
: removal of pathogenic micro-organisms that remain
after washing
3
Rinsing
4
Drying
22.1
Cleaning products
Use
(Fig.15)
- clean water at maximum temperature of 30°C
- soft cloth
- mild and neutral detergents