M al ag a
E n g l i s h
05060172 00 11-07-2017
3 4
Installation
procedure
(Fig.4)
CAUTION
! Accidental door opening. Injury.
Keep the doors closed and locked during installation.
Pitch
Action
1
carefully examine the installation area, eliminating any danger to the
operator;
2
remove the package only if the cabinet is placed in the operation area
3
lift the cabinet safely
4
use suitable scissors to cut the clip tightening straps-A-
5
remove the clips and the frame
6
lower and place the cabinet in the area of use
7
adjust the horizontal position of the cabinet using a spirit level (Fig.8)
8
check that all feet are into contact with the floor
9
level the cabinet both in front and back
What to avoid
DO NOT install the cabinet (Fig.9):
- in areas at risk of explosion
- in open air and therefore subjected to atmospheric agents;
- near heat sources (direct sunlight, heating systems, incandescence lamps, etc.)
- in the vicinity of air currents (close to doors, windows, air-conditio-
ning systems, etc.) that exceed a speed of 0.2 m/s
Firts cleaning
•
gently remove the protective film, eliminate glue residues with suitable sol-
vents
•
use neutral products, dry with a soft cloth
DO
NOT use alcohol to clean the methacrylate (Plexiglas) parts
DO
NOT use abrasives or metal sponges
ATTENTION!: failure/breakage.
DO NOT walk on cabinet's roof(Fig.13).
CAUTION
! Discarded packing parts. Injury.
Do
not leave packing parts (nails, wood, staples, etc.) and tools used for the operation (pliers,
scissors, etc.) in the working area.
These objects must be removed with appropriate means and taken to their respective col-
lection places.
i
For correct disposal, the package consists of:
Wood - Polystyrene - Polythene - PVC - Cardboard.
14. Wiring
DANGER! Live parts. Electrocution.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
ensure that the casing does not come into contact with the electrical panel
Provide a suitable grounding system!
i
The systems must be set up in accordance to the norms that regulate manufacture, installa-
tion, use, and maintenance foreseen by the norms in force in the country where the cabinet
is installed.To ensure normal operation, the maximum variation of the voltage must range
b/- 6% of the nominal value.