Malmoe 3
English
16
05060081 00 08/11/2007
7
Max. absorbed current
8
Electrical power absorbed at steady state during refrigerating phase (fans + hot lighting)
9
Electrical power absorbed at steady state during defrosting phase (heating el hot cables
+ fans + lighting)
10 Illuminating power (where applicable)
11 Useful display surface
12 Type of refrigerating fluid used in the appliance
13 Mass of refrigerating gas loaded in each individual appliance (only for cabinets with incorporated
motor)
14 Environmental climatic class and reference temperature
15 Class of protection against humidity
16 Manufacturing job number of the cabinet
17 Manufacturing order number of the cabinet
18 Manufacturing year of the cabinet
In case of technical service request, please communicate the following information for the
identification of the cabinet:
- product name (Fig. 2 - 2);
- registration number (Fig. 2 - 4);
- job number (Fig. 2 - 18).
5. Transportation (Fig. 3)
The cabinets are fitted with a wooden support fixed to the base for handling by means of fork-lifts.
Use a manual or electrical lift truck suitable for raising the cabinet in question.
6. Receipt and first cleaning
Upon receipt of the cabinet:
- Make sure that the packaging is intact and that it is not evidently damaged;
- Unpack the cabinet with care so as not to damage the cabinet itself;
- Check each single part of the cabinet, making sure that all its components are intact;
- If anything is found to be damaged, call the supply company immediately;
- Proceed with a first cleaning using neutral products, dry with a soft cloth, do not use abrasive
substances or metal sponges.
- For correct packaging disposal, remember that it contains:
Wood - Polystyrene - Polythene - PVC - Cardboard.
7. Installation and environmental conditions (Fig. 3)
For installation, follow the instructions below:
- Do not position the cabinet:
in places containing explosive gaseous substances;
in the open air and, therefore, exposed to atmospheric agents;
near sources of heat (direct sunlight, heating appliances, incandescent lights etc.);
near air current (near doors, windows, air-conditioning systems etc.) which exceed the speed of
0.2 m/sec
.
- Remove the wooden supports on the base (used for transportation) and mount the adjustable feet
(Rif. 2) regulating them so as to position the cabinet horizontally. Use a level (Rif. 1) to make sure of
its positioning.
- If the cabinet is moved, repeat the level check.
- Before connecting the cabinet to the electric supply, make sure that all the data on the nameplate
corresponds to the characteristics of the electrical system to which it will be connected.
- In order for the cabinet to operate correctly, the temperature and the relative environmental
temperature must respect the parameters indicated in regulation
EN-ISO 23953 - 1/2
which gives
Climatic Class 3 (
+25°C; U.R. 60%
).
N.B.All these operations must only be carried out by specialised technical personnel.