Victoria
English
05060124 00 19/12/2011
27
11.Combining cabinets (Rif. 20) -
specialized technician -
To combine two or more cabinets in channel, proceed as follows:
z
Disassemble the shoulders (if present).
z
Position the cabinets side by side
z
Join the risers and the brackets, using the screws supplied
z
Make sure the alignment pins are inserted in their provided seats.
CHANNEL COMBINATION KIT
12.Electrical connection (Rif. 21) -
specialized technician
-
It is the Client's responsibility to arrange the electrical power supply line up to the point
of connection to the cabinet. Sizing of the electrical power supply line must be
performed in accordance to the power absorbed by the cabinet (see Technical Data).
z
Remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
z
Consult the wiring diagrams before performing the connection.
z
Check that power supply voltage is the one reported on the rating plate.
z
Instruct the operator on the position of the switch so that it may be timely reached
in case of an EMERGENCY.
z
To ensure normal operation, the maximum variation of the voltage must range
b/- 6% of the nominal value.
Once you have inserted th handle, let go of the lock spring
The spring will release a snapping sound to confirm the
glass panel is locked
Position the glass panel correctly
Pos.
Denomination
Code
Pcs
.
1
Alignment pin Ø 4x80
02940652
7
2
Screw TCEI M8x50 (galvanized) 04711041
2
3
Nut M8
04230600
2
4
Washer Ø 6x12
04480103
2
5
Screw TCEI M8x50 (galvanized) 04711098
3
6
Nut M6 (galvanized)
04230400
3
BEFORE ANY OPERATION REMOVE VOLTAGE TO THE SYSTEM!
The electrical
system must have a grounding connection!
z
The systems must be set up in accordance to the norms that regulate
manufacture, installation, use, and maintenance foreseen by the norms in
force in the country where the cabinet is installed.
z
ARNEG Spa rejects any responsibility toward the user and third parties for
damages caused by breakdowns or malfunctions of the systems arranged
upstream of the cabinet and for damages to the cabinet that stem from causes
directly ascribable to an electrical system malfunction.
z
The cabinet must be protected upstream with an automatic, omnipolar
magneto-thermal switch having adequate characteristics and which will serve
as the main line disconnecting switch.