Page 11
V.
Start-Up -
Primimg the
AromaMist
AromaMist
AromaMist
AromaMist
pump
CAUTION: Please read all 7 steps prior to priming the
AromaMist
AromaMist
AromaMist
AromaMist
pump
1.
Insert
AromaMist
AromaMist
AromaMist
AromaMist
pump power supply cord into pump power supply module.
2.
Insert
AromaMist
AromaMist
AromaMist
AromaMist
pump power supply module into grounded 110V AC outlet.
3.
Power up integral
AromaMist
AromaMist
AromaMist
AromaMist
pump rocker switch located on the pump panel
face. Switch LED will light when on.
4.
Initiate the remote-mounted aroma switch by pressing gently on jet icon.
Aroma LED will light when on and pump will start moving aroma oil.
5.
With
AromaMist
AromaMist
AromaMist
AromaMist
pump on, push and hold the priming button located on the
pump panel face. This will initiate the priming process where aroma oil will be
drawn at a faster rate to fill the suction and discharge tubing. Releasing prime
button will stop priming process.
6.
With pump in priming mode, if fluid begins moving up suction tubing without
hesitation, bleed valve adjustment is not required. If fluid is not moving up suction
line, open bleed valve (counter-clockwise) approximately one (1) turn or until fluid
begins to move. When fluid level reaches the pump head assembly, close bleed
valve allowing fluid to flow through pump head and up to the steam line.
NOTE:
Do not over tighten bleed valve as damage may occur.
7.
Once aroma oil has reached the 3-function valve, release the priming tubing
and turn off the remote-mounted aroma switch.
AromaMist
AromaMist
AromaMist
AromaMist
pump is now ready
for use.
NOTE: Pump integral On/Off rocker switch must stay in the on position to
operate pump from remote-mounted aroma switch.