Congratulations, you have just purchased the world’s most advanced aroma oil 
metering pump, the 

AromaMist

AromaMist

AromaMist

AromaMist

 

pump. 

 
This instruction manual covers all facets of the installation and operation of the 

AromaMist

AromaMist

AromaMist

AromaMist

 

pump including unpacking, mounting, electrical, plumbing, control, pump 

connections, and start-up. 
 
All information in these instructions is based on the latest product information available 
at the time of publication.  Accurate Industries Et Al., Inc. reserves the right to make 
changes at any time without notice.  Please read this manual completely before 
proceeding. 
 
Observe safety protocols and heed all warnings and precautions for safe and efficient 
installation and operation of the 

AromaMist

AromaMist

AromaMist

AromaMist

 pump.

 

 

WARNING: It is recommended to have a certified licensed electrician 
and plumber install the 

AromaMist

AromaMist

AromaMist

AromaMist

 

pump system. 

 
 

II.  Safety and Operating Information 

 

CAUTION: Please read this manual in its entirety prior to installing or 
operating the 

AromaMist

AromaMist

AromaMist

AromaMist

 pump system. 

 

A. Chemical Compatibility 

AromaMist

AromaMist

AromaMist

AromaMist

 

metering pumps are designed to work with 

AromaMist

AromaMist

AromaMist

AromaMist

 oils only.  

Failure to do so may void the warranty or pose serious health hazards. 
 

B. Safety Equipment and Preparation 

Always wear the proper protective clothing and gear when working around 
chemicals and chemical metering pumps. Safety glasses, gloves, and aprons can 
prevent accidental exposure to chemicals. 
 

C. In Case of Accident 

If a chemical spillage occurs, consult the Material Safety Data Sheet (MSDS) for 
specific instructions regarding the chemical being used. 

 

D. Liquids Under Pressure 

Liquids under pressure can present a special hazard when a line or seal is 
punctured resulting in the spraying of chemical many yards away. 

 

E. Safe Installation 

Do not install the 

AromaMist

AromaMist

AromaMist

AromaMist

 

pump system without reading and understanding the 

Operation Warning section (V) and Operation section (VII) of this manual. 

Summary of Contents for AI-5

Page 1: ...AromaMist AromaMist AromaMist AromaMist Pump Model AI 5 Installation and Operation Manual rev 3z 9505...

Page 2: ...on 3 II Safety and Operating Information 3 III Pump Package Contents 4 IV Installation A Location 4 B Mounting The Pump 4 C Electrical 5 D Plumbing 5 E Control Aroma Switch 6 F Typical Installation 7...

Page 3: ...tem II Safety and Operating Information CAUTION Please read this manual in its entirety prior to installing or operating the AromaMist AromaMist AromaMist AromaMist pump system A Chemical Compatibilit...

Page 4: ...ient to the aroma oil supply and a source of power for the pump Do not install the pump in a location where the ambient temperature exceeds 100 degrees Fahrenheit or where water can freeze A location...

Page 5: ...utput This predictability can only be maintained if all fitting sizes remain unaltered Do not attempt to reduce tubing size All tubing connection should be double checked to insure against leakage CAU...

Page 6: ...ing an aroma switch mounted inside the steam room is most preferred 2 Mounting Aroma Switch Make a 1 diameter hole in desired control location Route the aroma switch integral control cable from the wa...

Page 7: ...ist AromaMist AromaMist AromaMist Pump Installation 1 Verify carton components and mount pump on a level surface See details on locating the pump on page 4 of this manual 2 Locate AromaMist AromaMist...

Page 8: ...ads 7 Thread suction tubing through aroma container 7 16 hole and insert components into aroma oil container Foot valve should remain vertical and resting on aroma container bottom 4 Beginning with th...

Page 9: ...bove 13 Locate 3 function valve apply Teflon tape or joint compound to NPT threads and secure 3 function valve in bottom of T 10 Cut required length of discharge tubing remove discharge valve tubing n...

Page 10: ...of pump installation location and insert pump power supply module 18 Locate pump switch with integral 3 pin 60 low voltage cable 19 Cut a 1 hole in desired switch installation location and run control...

Page 11: ...ed on the pump panel face This will initiate the priming process where aroma oil will be drawn at a faster rate to fill the suction and discharge tubing Releasing prime button will stop priming proces...

Page 12: ...ue steam shower condensation and moisture will cause the steam room floor and other surfaces to become slippery Installation of non skid floor materials and caution while walking is always recommended...

Page 13: ...ting and stopping of aroma oil will not adversely affect the AromaMist AromaMist AromaMist AromaMist pump The AromaMist AromaMist AromaMist AromaMist pump has no adjustment for aroma oil flow rate For...

Page 14: ...o prime Inspect check valves in fluid end for cleanliness Clean or replace as necessary Inspect suction tube through its full length to assure that there are no kinks or other restrictions Check fluid...