C. Electrical
AromaMist
AromaMist
AromaMist
AromaMist
pump model AI-5 is a 120V AC pump and has a voltage regulated
internal power supply capable of operating in the range of approximately 95 to
135 VAC. Use a supply voltage of 100 to 120 VAC for best results. The 3-wire
grounded plug must be used with provided power supply module in a 3-wire
grounded wall outlet.
CAUTION: Never remove ground wire from plug.
CAUTION: Do not position power supply cord in direct contact
with steam line.
D. Plumbing
1. Tubing Connections
The
AromaMist
AromaMist
AromaMist
AromaMist
pump uses carefully matched components to achieve a
predictable metering output. This predictability can only be maintained if all fitting
sizes remain unaltered.
Do not
attempt to reduce tubing size. All tubing
connection should be double checked to insure against leakage.
CAUTION: Do not position tubing in direct contact with steam
line.
NOTE: When cutting lengths of tubing for your installation, ensure a
clean, square cut. Use short lengths of tubing whenever possible.
2. Tubing nuts
Do not over tighten tubing nut connectors. Tighten no more than ¼” turn after
the fitting contacts the seal. Hand tighten only.
Do not use a wrench or pliers
as they may damage the fittings. (See diagram below.) Do not use Teflon tape
except on 3-function valve NPT fitting.
Be sure to observe applicable local
plumbing codes.
WARNING: Clear flexible vinyl priming tubing is not intended for
pressurized or pump discharge use.
3. Tubing Connections