G. Step By Step
AromaMist
AromaMist
AromaMist
AromaMist
Pump Installation (continued)
Page 9
9. Remove intake valve tubing nut and
red protective cap, slip nut on the
suction tubing, secure suction tubing on
intake valve and hand tighten intake
valve nut.
11. All pump priming, discharge and
suction tubing connections should
appear as detailed above.
13. Locate 3-function valve, apply Teflon
tape or joint compound to ½” NPT
threads and secure 3-function valve in
bottom of ½” T.
10. Cut required length of discharge
tubing, remove discharge valve tubing
nut and red protective cap, slip nut on
discharge tubing, secure discharge
tubing and hand tighten nut.
12. Cut existing steam generator steam
line and solder in provided ½” brass T.
Steam outlet head shown for illustration
purposes only.
14. Remove 3-function valve tubing nut,
slip nut on discharge tubing and hand
tighten nut to 3-function valve.