SC-350/SC-360
–
User’s
Guide
–
019223-101
Rev
06
8
Operation
WARNING!
Risk of jamming!
Follow the safety Precautions.
Modes of Operation
The SC-350/360 has two modes of operation, continuous counting
and batch counting.
Continuous counting
The machine counts the coins and the display is continuously
updated with the number of coins counted.
The green indicator above
Start/Stop
is lit up during operation.
• If the green indicator flashes, the inspection cover is open.
• The green indicator stops flashing when the inspection cover is
closed. It is possible to restart the machine.
If no coin passes the coin sensor for five seconds, the rotating disc
stops and automatically reverses slightly before restarting. If no coin
passes during the next five seconds the disc stops automatically.
This happens because:
• there are either no more coins to count, or
• the flow of coins has been blocked.
This function can be turned off (see
Batch counting
The machine counts the coins up to a fixed batch stop and then
stops. There are seven fixed batch stops: 20, 40, 50, 1,000, 2,000,
4,000 and 5,000.
In addition to these there is a temporary batch stop which can be
set between 5 and 1,000,000. The temporary batch stop can be used
if there is no suitable fixed batch stop.
The fixed batch stops can be changed, see
.
The green indicator above
Q
is lit when the machine is set for
counting a fixed quantity, a batch stop. When the green indicator
flashes, a full batch has been counted, that is the batch stop has
been reached.
Summary of Contents for SCAN COIN SC-350
Page 1: ......
Page 2: ...SC 350 SC 360 User s Guide 019223 101 Rev 06...
Page 3: ...SC 350 SC 360 User s Guide 019223 101 Rev 06...
Page 23: ......