Multifunction LCD Digital Timer
Explanation of functions
Forecast / Absolute Value (set1)
For details, refer to the following figure.
Time Range (timr)
Set the range to be timed in the range 000.000s to 999999h.
Output Mode (outm)
Set the output mode. The possible setting are A and F-1
For details on output mode operation, refer to “timing charts”.
Input signal width (iflt)
Set the minimum signal input width (20ms or 1ms) for signal, reset, and gate inputs.
NPN / PNP Input Mode (imod)
Select NPN input (no-voltage input) or PNP (voltage input) as the input format. The same setting is used for
all external inputs. For details on input connection, refer to “input connections” on page 25.
Key Protection Level (kypt)
When the key protection switch is ON, it is possible to prevent setting error by prohibiting the use of certain
operation keys by specifying K/P level (KP-1 toKP-5). For details, refer to “Key Protection Setting Mode” on
page 8.
■
Forecast Value Setting
Example: F-1 Mode
Forecast
set value
Forecast
output (OUT1)
Control
output (OUT2)
Set value
Forecast
value
0
Present value
OUT1 (forecast output) turns ON when the
present value reaches the forecast value.
forecast value = set value-forecast set value
The forecast set value is used to set the
deviation for the set value.
OUT2 (control output) turns ON when the
present value reaches the set value.
If the forecast set value ≥ set value, OUT1
(forecast output) turns ON as soon as timing
starts.
.
2
.
3.
Absolute Value Setting
Example: F-1 Mode
Control output 1 (OUT1)
Control output 2 (OUT2)
Set value 2
Set value 1
0
Present value
OUT1 (control output 1) turns ON when the
present value reaches the set value .
OUT2 (control output 2) turns ON when the
present value reaches the set value 2.
.
2
.