5
Multifunction LCD Digital Counter
Input/Output Mode Setting(Counter)
Operation for -stage models is the same as that for
OUT2.
When using a 2-stage model as a -stage counter, or
dual counter, total and preset counter, OUT and OUT2
turn ON and OFF simultaneously.
Output mode
UP
DOWN
UP/DOWN A, B, C
Operation after
count completion
N
T h e o u t p u t s a n d
present value display
are held until reset/
reset is input.
F
The present value
display continues to
increase/decrease.
The outputs are held
until reset/reset is
input.
C
As soon as the count
value reaches SV,
the present value
display returns to the
reset start status. The
present value display
does not show the
present value upon
count-up. The outputs
r e p e a t o n e - s h o t
operation. OUT self-
holding output turns
OFF after the OUT2
o n e - s h o t o u t p u t
time. The OUT one-
s h o t o u t p u t t i m e
is independent of
OUT2.
R
The present value
display returns to the
reset start status after
the one-shot output
t i m e . O U T s e l f -
holding output turns
OFF after the OUT2
o n e - s h o t o u t p u t
time. The OUT one-
s h o t o u t p u t t i m e
is independent of
OUT2.
Note:
The full scale (FS) for TC-Pro 6-digit models is 999999.
When the present value reaches 999999, it returns to 0.
Counting can not be performed during reset/reset input.
If reset/reset is input while one-shot output is ON, one-shot output turns OFF.
Do not use the counter function in applications where the count may be completed (again) while
one-shot output is ON.
■
.
2.
3.
4.
5.
(the one-shot output time can be
set in the range 0.001to 999.999s)
Self-holding
output
One-shot One-shot output
Output mode setting