7
Multifunction LCD Digital Counter
(the one-shot output time can be set in the range 0.001to 999.999s)
Self-holding
output
One-shot One-shot output
Output mode
UP/DOWN A, B, C
Operation after count
completion
K-2
The display continues to increase/
decrease until the overflow or
underflow value is reached. One-
shot output only.
D
The display continues to increase/
decrease until the overflow or
underflow value is reached. The
outputs are ON while the count is
equal.
L
The display continues to increase/
decrease until the overflow or
underflow value is reached. OUT1
is held while the present value is
less than or equal to set value .
OUT2 is held while the present
value is less than or equal to set
value 2.
A
The display continues to increase/
decrease until the overflow or
underflow value is reached. OUT1
is held while the present value is
less than or equal to set value .
OUT2 is held while the present
value is less than or equal to set
value 2.
Note: H mode is available for
2-stage models only.
Note:
Counting can not be performed during reset/reset input.
If reset/reset is input while one-shot output is ON, one-shot output turns OFF.
Do not use the counter function in applications where the count may be completed (again) while
one-shot output is ON.
.
2.
3.
Output mode setting