AS-309H Surge Arrestor 

Operation and Installation 

(For one or two wire transmission lines) 

 

 

 

                               AS-309H Single Wire or Two Wire Arrestor 

 

 

Rating 5 kW CW and Peak Power at High VSWR 

– approximately 3000 V GDT  

 

20 kA rated per tube  

 

1 MHz to 60 MHz  

 

Stainless steel hardware

 

 

Water-tight Nema-4X/6P harsh environment enclosure.

 

 

The  main  difference  between  this  arrestor  and  others  is  the  use  of  a  static  bleed  component  in 
combination  with  a  gas  discharge  tube  (GDT).  The  high  voltage  bleeder  in  the  AS-309H 
suppressor  is  constantly  draining  static  and  voltage  charge  build  up  from  the  antenna.  It  also 
relieves  the  gas  tube  from  handling  the  current  that  would  cause  voltage  build  up  and  would 
ultimately  lead  the  tube  to  fire.  This  can  happen  before  the  gas  tube  conducts,  as  gas  tubes 
exhibit  a  delay.    In  addition,  the  suppressor  appears  as  a  mismatched  load  when  a  surge  is 
applied (combined operation of these components and gas tube) and much of the surge energy is 
reflected  back  to  the  antenna.  The  antenna  is  also  a  mismatched  load  to  much  of  the  surge 
energy, so some of that energy is reflected back to the surge  arrestor, and goes back and forth.  
In the process, the energy is dissipated in both the feed line and the arrestor. 