Other useful aspects of the PowerMaster II:
VSWR is not displayed if the forward power is less than 1 watt with a 3 kW coupler or 2 watts with a 10 kW coupler.
VSWR alarm function is disabled if the forward power is less than 10 Watts in Forward modes or less than 50 Watts in V (Reflected) mode.
(20 & 100 Watts respectively for a 10 kW coupler).
The minimum displayed power is 0.5 watt. The maximum displayed power is 3030 Watts (3 kW HF coupler).
Under 100 Watts the meter will display power in tenths of a watt. Under 10 watts, the meter will display in hundredths of a watt.
The call sign/message which you can program into the display can be up to16 characters long. You must connect to a computer to program your
callsign.
The bar graph has 80 segments and auto ranges in 3 ranges.
Display will auto dim after 2 minutes and automatically turn off after 10 minutes if no power is detected.