Appendix
17.
17.1. Troubleshooting
Operation
Problem
Possible Cause
Remedy
Blown fuse
12 V or 24 V output overload.
Camera is equipped with self-resetting thermal fuses.
To reset, disconnect all accessories and wait for one minute.
Camera Display: Monitoring
Defective
fps
Fault in the electronic control of
the mirror shutter drive system.
CAUTION: May result in faulty exposure!
Warning can be overridden by switching camera’s main switch off
and on. If “Monitoring Defective” is overridden, additional faults
in electronic control of drive system will not be detected.
Camera won’t start in
low temperatures.
Camera may not start/
run unstable in ambient
temperatures below 0 °C/32 °F.
ARRI or its subsidiaries do not assume responsibility for damage if
camera is operated outside specified operating temperature range.
Turn on camera at least an hour before shooting with ambient temperature
not lower than 0 °C/32 °F. Then take heated camera outside.
Cover camera with a blanket if necessary.
Diagnostics LED red.
One or more system
checks failed.
Restart camera. Perform standard reset and restart camera.
Take camera to ARRI service center if problem persists.
Flash Mag does not turn on
when connected to Flash Mag
Mounting Adapter FMA-1.
Flash Mag Adapter not turned on.
Power on Flash Mag Adapter using power switch on left side of adapter.
No access to camera control
functions or video menu.
LOCK switch engaged.
Disengage LOCK switch above camera left side display.