Getting Started with EBB 200/400
29
Getting Started with EBB 200/400
1
Check to ensure that
ballast is switched off
(see picture 4 on
page 25).
2
Nominal EB wattage
must match nominal
lamp power.
3
Ensure that a func-
tional lamp is installed in
lamphead. Immediately
replace all lamps with
any visible damage or
thermal deformation.
4
Connect lamphead
to ballast, using original
ARRI cables (lamp con-
nector 400 W).
5
Connect ballast to a
suitable DC-power sup-
ply (see page 77).
¡
When operating a
400 W lamp,
both
power-supply cables
of the EBB must be
connected
to a suitable
DC-power supply.
¡
When using two bat-
teries, check to ensure
that they are of the
same type (e.g. NiCd),
have the same capacity
and show identical
charging status.
¡
Check that both
fuses (see picture 4 on
page 25) on ballast’s
front panel are in their
ON
position.
I
In case batteries are
different, or in case
only one battery is
connected, the cur-
rent drawn by bal-
last will not be split
equally between the
two power-supply
cables. This may
result in one of the
two fuses tripping. If
this happens, allow
some five minutes for
fuse to cool down,
before it can be
switched on again.
6
To strike lamp, push
key
ON
on EBB’s front
panel. The green LED
will be lit.
¡
Lamp will strike
about 2 to 5 seconds
later. If lamp does not
strike, see trouble shoot-
ing guide on page 83.
7
After lamp has
reached its operating
temperature (after
approx. 6 minutes), its
intensity can be
adjusted in the range of
50 to 100% by turning
the dimming potentio-
meter.
When dimming potenti-
ometer is fully turned to
the left, intensity is set to
‘minimum’. Turning dim-
ming potentiometer to
the right (in clockwise
direction) will increase
intensity until ‘maximum’
is reached at the right
stop.
I
Caution: Danger of
over-heating!
Never
block ventilation slots
of EBBs.
29
BALLASTS
Summary of Contents for arrilux 400 lighthouse
Page 6: ...Übersicht 6 Übersicht 1 9 8 7 6 5 4 3 2 13 17 16 15 14 10 12 11 18 6 6 DAS PRODUKT ...
Page 72: ...Technische Daten Scheinwerfer 72 Abmessungen Technische Daten PAR LITE A 30 9 B 294 300 ...
Page 73: ...Technical Data of Lampheads 73 Dimensions Technical Data ...
Page 79: ...79 APPENDIX Bild Picture 50 Bild Picture 51 ...
Page 91: ...TÜV GS Zertifikat TÜV GS Certificate 91 APPENDIX TÜV GS Zertifikat TÜV GS Certificate ...
Page 93: ...CB Test Zertifikat CB Test Certificate 93 CB Test Zertifikat CB Test Certificate APPENDIX ...